The impact of pipeline changes and temperature increase in a hospital historically colonised with Legionella

dc.contributor.authorQuero, Sara
dc.contributor.authorPárraga Niño, Noemi
dc.contributor.authorGarcía Núñez, Marian
dc.contributor.authorPedro Botet, Maria Luisa
dc.contributor.authorGavaldà, L.
dc.contributor.authorMateu, Lourdes
dc.contributor.authorSabrià, M.
dc.contributor.authorMòdol, Josep M.
dc.date.accessioned2021-03-15T12:25:54Z
dc.date.available2021-03-15T12:25:54Z
dc.date.issued2021-01-21
dc.date.updated2021-03-11T11:40:49Z
dc.description.abstractHealthcare-related Legionnaires' disease has a devastating impact on high risk patients, with a case fatality rate of 30-50%. Legionella prevention and control in hospitals is therefore crucial. To control Legionella water colonisation in a hospital setting we evaluated the effect of pipeline improvements and temperature increase, analysing 237 samples over a 2-year period (first year: 129, second year: 108). In the first year, 25.58% of samples were positive for Legionella and 16.67% for amoeba. Assessing the distance of the points analysed from the hot water tank, the most distal points presented higher proportion of Legionella colonisation and lower temperatures (nearest points: 6.4% colonised, and temperature 61.4 °C; most distal points: 50% and temperature 59.1 °C). After the first year, the hot water system was repaired and the temperature stabilised. This led to a dramatic reduction in Legionella colonisation, which was negative in all the samples analysed; however, amoeba colonisation remained stable. This study shows the importance of keeping the temperature stable throughout the circuit, at around 60 °C. Special attention should be paid to the most distal points of the circuit; a fall in temperature at these weak points would favour the colonisation and spread of Legionella, because amoeba (the main Legionella reservoir) are not affected by temperature.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.pmid33479467
dc.identifier.urihttps://hdl.handle.net/2445/175109
dc.language.isoeng
dc.publisherSpringer Science and Business Media LLC
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1038/s41598-021-81625-6
dc.relation.ispartofScientific Reports, 2021, vol. 11, num. 1916
dc.relation.urihttps://doi.org/10.1038/s41598-021-81625-6
dc.rightscc by (c) Quero, S. et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationLegionel·la
dc.subject.classificationInfeccions nosocomials
dc.subject.classificationHospitals
dc.subject.otherLegionella
dc.subject.otherHospitals
dc.subject.otherNosocomial infections
dc.titleThe impact of pipeline changes and temperature increase in a hospital historically colonised with Legionella
dc.typeinfo:eu-repo/semantics/article

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
s41598-021-81625-6.pdf
Mida:
1.12 MB
Format:
Adobe Portable Document Format