Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Tots els drets reservats

Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/101342

Latex and nonlatex orthodontic elastics: in vitro and in vivo evaluations of tissue compatibility and surface structure

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Objective: to test the null hypothesis that there is no difference between latex and nonlatex orthodontic elastics with respect to tissue compatibility and surface structure. Materials and methods: latex and nonlatex elastics were implanted in the subcutaneous connective tissue of 45 Wistar rats. In the control groups, no material was implanted (sham). After 24 hours, 3, 7, 14, and 21 days, the animals were euthanized; tissue samples were processed and analyzed by descriptive and semi-quantitative microscopic analysis and quantification of plasma extravasation. The surface structure of elastics was evaluated by scanning electron microscopy (SEM). The results were analyzed by analysis of variance (ANOVA), Tukey test and Kruskal-Wallis test at 5% significance level. Results: peri-implant plasma extravasation was significantly higher (P < .05) in the animals that received latex elastics compared with those with nonlatex elastics and those that were control animals. The microscopic analysis revealed a more intense inflammatory infiltrate in the initial periods without statistically significant difference (P > .05) between the experimental and control groups. The SEM analysis revealed that the latex elastics presented microspheres and porosities, while the nonlatex elastics exhibited crystals on their surface and absence of porosities. Conclusion: the null hypothesis was rejected since the latex elastics were more irritating to the connective tissue than the nonlatex elastics in the initial periods and presented a more porous surface.

Citació

Citació

MARTÍNEZ COLOMER, Sara, GATÓN HERNÁNDEZ, Patrícia, ROMANO, Fábio lourenço, ROSSI, Andiara de, FUKADA, Sandra yasuyo, NELSON FILHO, Paulo, CONSOLARO, Alberto, SILVA, Raquel assed bezerra da, SILVA, Léa assed bezerra da. Latex and nonlatex orthodontic elastics: in vitro and in vivo evaluations of tissue compatibility and surface structure. _The Angle Orthodontist_. 2015. Vol. 86, núm. 2, pàgs. 278-284. [consulta: 23 de gener de 2026]. ISSN: 0003-3219. [Disponible a: https://hdl.handle.net/2445/101342]

Exportar metadades

JSON - METS

Compartir registre