Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by (c) Páez Carpio et al., 2025
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/221363

Cone beam CT pulmonary angiography in balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension during the program initiation period

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

AIM Cone beam CT pulmonary angiography (CBCT-PA) has proven to be a valuable technique during balloon pulmonary angioplasty (BPA) for chronic thromboembolic pulmonary hypertension (CTEPH) in established centres. This study aimed to demonstrate the safety and efficacy of CBCT-PA-guided BPA for CTEPH during the initial period of a BPA program. CBCT-PA improves procedural accuracy by visualising distal thromboembolic lesions and providing real-time guidance, which is critical during program initiation. MATERIALS AND METHODS This single-centre, single-arm study prospectively evaluated patients with CTEPH undergoing BPA from 2017 to 2022. Outcomes of interest included pre-BPA and post-BPA 6-minute walking distance, New York Heart Association Functional Classification (NYHA-FC), mean pulmonary artery pressure (mPAP), pulmonary vascular resistance (PVR), N-terminal pro B-type natriuretic peptide (NT-proBNP), and BPA-related adverse events (AEs). Statistical analysis compared pre-BPA and post-BPA results. CBCT-PA was used for three-dimensional (3D) vascular mapping and precise lesion targeting. RESULTS Ninety BPA sessions were performed on 19 patients under CBCT-PA guidance. Significant improvements were observed in mPAP (37.0 mmHg [interquartile range (IQR): 28.0-46.0] vs 25.5 [IQR: 22.8-31.5]; P<0.001), PVR (5.5 Wood units [IQR: 3.4-8.5] vs 3.3 [IQR: 2.7-4.6]; P < 0.001), NYHA-FC I-II rate (8 [42%] vs 18 [94%]; P = 0.04), and NT-proBNP (165 pg/mL [IQR: 82-1146] vs 127.0 [IQR: 57-216]; P = 0.014). Overall AE rate was 14.4%, and major AE rate was 7.7% (all Cardiovascular and Interventional Radiology Society of Europe [CIRSE] grade 3). The haemoptysis rate was 4.4%. No periprocedural deaths were reported. CONCLUSION BPA performed under CBCT-PA guidance appeared to be an effective and safe approach in the program's initial period, helping achieving similar results as established centres.

Citació

Citació

PÁEZ CARPIO, Alfredo, ZARCO CONTRERAS, Federico xavier, SERRANO ALCALÁ, Elena, VOLLMER, Ivan, PUIG, José, BARBERÀ I MIR, Joan albert, GOMEZ, F. m., BLANCO VICH, Isabel. Cone beam CT pulmonary angiography in balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension during the program initiation period. _Clinical Radiology_. 2025. Vol. 84. [consulta: 25 de febrer de 2026]. ISSN: 0009-9260. [Disponible a: https://hdl.handle.net/2445/221363]

Exportar metadades

JSON - METS

Compartir registre