Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Doctoral thesis

Version

Published version

Publication date

All rights reserved

Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/42821

Immunochemical methods for biomonitoring of chlorophenols as potential biomarkers of exposure

Journal Title

Journal ISSN

Volume Title

Related resource

Abstract

[eng] The thesis presents the development of immunochemical methods for detection of trichlorophenols (TCP) in environmental and biological samples. An indirect enzyme linked immunosorbent assay (ELISA) for 2,4,5-TCP has been developed after a rational design of the immunizing hapten chemical structure, and the screening of 12 competitor haptens. The effect of the conjugation degree of the competitors and their homology with the target analyte, the physicochemical parameters (pH, ionic strength), the concentration of detergent, the time of incubation and the specificity were studied. Two immunoassays (2,4,5- and 2,4,6-TCP ELISAs) were evaluated for the analysis of water, milk, serum and urine. Drinking water was analyzed directly after buffering the sample. The strong matrix effects in milk samples requires the sample clean up. Human serum can be analyzed after protein precipitation with absolute ethanol. The strong matrix effect of urine and its variability for samples from different individuals suggested the introduction of a purification step prior to ELISA. The C18- solid phase extraction (SPE) is an effective clean up method to remove an important part of the nonspecific interferences present in urine. The C18-SPE-ELISA method allows accurate quantification of TCPs in urine of occupationally exposed persons. SPE based on immunosorbents (immunoaffinity extraction, IAE) have been developed in single and 96-column formats. IAE is an effective clean up method to remove all nonspecific urinary interferences. The IAE step was optimized regarding sample volume, loading level, type of urine hydrolysis washing and elution conditions. The selectivity of the immunosorbents can be modulated by the washing conditions. The immunosorbents have sufficient capacity to effectively extract 2,4,6-TCP from urine samples of occupationally exposed persons and the general population. The HTS-IAE-ELISA method allows the processing of 100 samples/day with very good precision and accuracy. The method was validated with GC-MS and applied to the biomonitoring of three groups of population from Catalonia. A quenching fluorescence immunoassay based on the laser-induced fluorescence detection in microdroplets (LIF-microdroplet-QFIA) for 2,4,6-TCP has been developed as a novel biodetection system. This approach offers significant improvement in method detectability compared to the microplate immunoassays and is the first application urine samples that can be directly analyzed after sample dilution.

Citation

Citation

NICHKOVA, Mikaela Ivanova. Immunochemical methods for biomonitoring of chlorophenols as potential biomarkers of exposure. ISBN 846882819X. [consulted: 13 of August of 2026]. Available at: https://hdl.handle.net/2445/42821

Export metadata

JSON - METS

Share record