Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Accepted version

Publication date

All rights reserved

Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/125467

Peripheral venous blood gases and pulse-oximetry in acute cardiogenic pulmonary oedema

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

Background: The role of venous blood gases as an alternative to arterial blood gases in patients with severe acute heart failure has not been established. Objective: To assess the correlation between arterial and peripheral venous blood gases together with pulse-oximetry (SpO2), as well as to estimate arterial values from venous samples in the first hours upon admission of patients with acute cardiogenic pulmonary oedema. Methods: Simultaneous venous and arterial blood samples were extracted on admission and over the next 1, 2, 3, 4, and 10 hours. SpO2 was also registered at the same intervals. Results: A total of 178 pairs of samples were obtained from 34 consecutive patients with acute cardiogenic pulmonary oedema. Arterial and venous blood gases followed a parallel course in the first hours, showing high correlation rates at all time intervals. Venous samples underestimated pH (mean difference −0.028) and overestimated CO2 (+5.1 mmHg) and bicarbonate (+1 mEq/l). Conversely, SpO2 tended to underestimate SaO2 (mean±SD: 93.1±9.1 vs. 94.2±8.4). Applying simple mathematical formulae based on these differences, arterial values were empirically calculated from venous samples, showing acceptable agreement in the Bland−Altman test. Likewise, a venous pH <7.32, pCO2 >51.3 mmHg, and bicarbonate <22.8 mEq/l could fairly identify arterial acidosis, either respiratory or metabolic, with a test accuracy of 92, 68, and 91%, respectively. Conclusions: In patients with cardiogenic pulmonary oedema, arterial blood gas disturbances may be estimated from peripheral venous samples. By monitoring SpO2 simultaneously, arterial punctures could often be avoided

Citation

Citation

MASIP, Josep (Masip i Utset), et al. Peripheral venous blood gases and pulse-oximetry in acute cardiogenic pulmonary oedema. European Heart Journal: Acute Cardiovascular Care. 2012. Vol. 1, num. 4, pags. 275-280. ISSN 2048-8726. [consulted: 10 of August of 2026]. Available at: https://hdl.handle.net/2445/125467

Export metadata

JSON - METS

Share record