Anatomical Modifications After Stent Implantation: A Comparative Analysis Between CGuard, Wallstent, and Roadsaver Carotid Stents

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Purpose: Carotid revascularization can be associated with modifications of the vascular geometry, which may lead to complications. The changes on the vessel angulation before and after a carotid WallStent (WS) implantation are compared against 2 new dual-layer devices, CGuard (CG) and RoadSaver (RS). Materials and methods: The study prospectively recruited 217 consecutive patients (112 GC, 73 WS, and 32 RS, respectively). Angiography projections were explored and the one having a higher arterial angle was selected as a basal view. After stent implantation, a stent control angiography was performed selecting the projection having the maximal angle. The same procedure is followed in all the 3 stent types to guarantee comparable conditions. The angulation changes on the stented segments were quantified from both angiographies. The statistical analysis quantitatively compared the pre-and post-angles for the 3 stent types. The results are qualitatively illustrated using boxplots. Finally, the relation between pre- and post-angles measurements is analyzed using linear regression. Results: For CG, no statistical difference in the axial vessel geometry between the basal and postprocedural angles was found. For WS and RS, statistical difference was found between pre- and post-angles. The regression analysis shows that CG induces lower changes from the original curvature with respect to WS and RS. Conclusion: Based on our results, CG determines minor changes over the basal morphology than WS and RS stents. Hence, CG respects better the native vessel anatomy than the other stents.Level of Evidence: Level 4, Case Series.

Citació

Citació

GINANNI CORRADINI, Luca, BALOCCO, Simone, MARESCA, Luciano, VITALE, Silvio, STEFANINI, Matteo. Anatomical Modifications After Stent Implantation: A Comparative Analysis Between CGuard, Wallstent, and Roadsaver Carotid Stents. _Journal of Endovascular Therapy_. 2022. Vol. 30, núm. 1, pàgs. 18-24. [consulta: 25 de febrer de 2026]. ISSN: 1526-6028. [Disponible a: https://hdl.handle.net/2445/196780]

Exportar metadades

JSON - METS

Compartir registre