Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services

dc.contributor.authorFlandes, Javier
dc.contributor.authorGiraldo Cadavid, Luis Fernando
dc.contributor.authorAlfayate, Javier
dc.contributor.authorFernández Navamuel, Iker
dc.contributor.authorAgustí García-Navarro, Carles
dc.contributor.authorLucena, Carmen M.
dc.contributor.authorRosell, Antoni, 1963-
dc.contributor.authorAndreo, Felipe
dc.contributor.authorCenteno, Carmen
dc.contributor.authorMontero,Carmen
dc.contributor.authorVidal, Iria
dc.contributor.authorGarcía Alfonso, Lucía
dc.contributor.authorBango, Antonio
dc.contributor.authorAriza, Miguel
dc.contributor.authorGallego, Rocío
dc.contributor.authorOrta, Marta
dc.contributor.authorBello, Salvador
dc.contributor.authorMincholé, Elisa
dc.contributor.authorTorrego, Alfons
dc.contributor.authorPajares, Virginia
dc.contributor.authorGonzález, Héctor
dc.contributor.authorWangüemert, Aurelio Luis
dc.contributor.authorPérez Izquierdo, Julio
dc.contributor.authorDisdier, Carlos
dc.contributor.authorVega Sanchez, Blanca de
dc.contributor.authorCordovilla, Rosa
dc.contributor.authorCascón, Juan
dc.contributor.authorCruz, Antonio
dc.contributor.authorGarcía López, J. Javier
dc.contributor.authorPuente, Luis
dc.contributor.authorBenedetti, Paola
dc.contributor.authorGarcía Gallo, Cristina L.
dc.contributor.authorDíaz Nuevo, Gema
dc.contributor.authorAguado, Silvia
dc.contributor.authorPartida, Concepción
dc.contributor.authorDíaz Agero, Prudencio
dc.contributor.authorLuque Crespo, Estefanía
dc.contributor.authorPavón, María
dc.contributor.authorPaez, Francisco
dc.contributor.authorCases, Enrique
dc.contributor.authorMartínez, Raquel
dc.contributor.authorBriones, Andrés
dc.contributor.authorFernández, Cleofe
dc.contributor.authorMartín Serrano, Concepción
dc.contributor.authorUribe Hernández, Ana Maria
dc.contributor.authorRobles, Josep Maria
dc.date.accessioned2021-02-09T08:49:34Z
dc.date.available2021-02-09T08:49:34Z
dc.date.issued2020-12-02
dc.date.updated2021-02-08T10:14:56Z
dc.description.abstractBackground: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist’s perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of cen‑ tral tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfed in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores>70/100 from the frst procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.pmid33267892
dc.identifier.urihttps://hdl.handle.net/2445/173768
dc.language.isoeng
dc.publisherBioMed Central
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1186/s12931-020-01576-w
dc.relation.ispartofRespiratory Research, 2020, vol. 21
dc.relation.urihttps://doi.org/10.1186/s12931-020-01576-w
dc.rightscc by (c) Flandes et al., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationBroncoscòpia
dc.subject.classificationSARS-CoV-2
dc.subject.otherBronchoscopy
dc.subject.otherSARS-CoV-2
dc.titleBronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
FlandesJ.pdf
Mida:
1000.4 KB
Format:
Adobe Portable Document Format