Dynamic model of the left ventricle for use in simulation of myocardial perfusion SPECT and gated SPECT
| dc.contributor.author | Bullich Roig, Santiago | cat |
| dc.contributor.author | Ros Puig, Domènec | cat |
| dc.contributor.author | Cot Sanz, Albert | cat |
| dc.contributor.author | Falcón, C. | cat |
| dc.contributor.author | Muxí Pradas, África | cat |
| dc.contributor.author | Pavía Segura, Javier | cat |
| dc.date.accessioned | 2012-05-03T11:24:32Z | |
| dc.date.available | 2012-05-03T11:24:32Z | |
| dc.date.issued | 2003 | |
| dc.description.abstract | Simulation is a useful tool in cardiac SPECT to assess quantification algorithms. However, simple equation-based models are limited in their ability to simulate realistic heart motion and perfusion. We present a numerical dynamic model of the left ventricle, which allows us to simulate normal and anomalous cardiac cycles, as well as perfusion defects. Bicubic splines were fitted to a number of control points to represent endocardial and epicardial surfaces of the left ventricle. A transformation from each point on the surface to a template of activity was made to represent the myocardial perfusion. Geometry-based and patient-based simulations were performed to illustrate this model. Geometry-based simulations modeled ~1! a normal patient, ~2! a well-perfused patient with abnormal regional function, ~3! an ischaemic patient with abnormal regional function, and ~4! a patient study including tracer kinetics. Patient-based simulation consisted of a left ventricle including a realistic shape and motion obtained from a magnetic resonance study. We conclude that this model has the potential to study the influence of several physical parameters and the left ventricle contraction in myocardial perfusion SPECT and gated-SPECT studies. | eng |
| dc.format.extent | 8 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 509874 | |
| dc.identifier.issn | 0094-2405 | |
| dc.identifier.uri | https://hdl.handle.net/2445/24865 | |
| dc.language.iso | eng | eng |
| dc.publisher | The American Association of Physicists in Medicine | |
| dc.relation.isformatof | Reproducció del document publicat a http://dx.doi.org/10.1118/1.1589497 | |
| dc.relation.ispartof | Medical Physics, 2003, vol. 30, num. 8, p. 1968-1975 | |
| dc.relation.uri | http://dx.doi.org/10.1118/1.1589497 | |
| dc.rights | (c) The American Association of Physicists in Medicine, 2003 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.source | Articles publicats en revistes (Ciències Fisiològiques) | |
| dc.subject.classification | Tomografia | cat |
| dc.subject.classification | Mètode de Montecarlo | cat |
| dc.subject.classification | Cor | cat |
| dc.subject.classification | Medicina nuclear | cat |
| dc.subject.other | Tomography | eng |
| dc.subject.other | Monte Carlo method | eng |
| dc.subject.other | Nuclear medicine | eng |
| dc.subject.other | Heart | eng |
| dc.title | Dynamic model of the left ventricle for use in simulation of myocardial perfusion SPECT and gated SPECT | eng |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion |
Fitxers
Paquet original