dc.description.abstractThe aim of this study was to evaluate the impact of autoclaving on the dimensional stability of surgical guides (SGs) for aesthetic crown lengthening (ACL) using different resins/printing methods. Fifty SGs for ACL were printed using five different resin/printer combinations (FL, SR, ND, KS and VC). All the SGs were scanned before (T0) and after (T1) sterilization. Autoclaving was conducted at 134 °C during 4 min. The STL files of each SG at T0 and T1 were compared with the original design (TR). Dimensional stability was measured using trueness and precision. Deviations from TR to T1 were calculated in the three space axes and by measuring the area between three reference landmarks. At T0, the FL group showed the best trueness and precision, while the SR group performed significantly worse than the other groups. At T1, all the groups except VC exhibited significant dimensional alterations compared with T0. Also, VC showed the best trueness and precision values. All the groups had a significant deviation in at least one space axis, while only the SR group exhibited significant variations from T1 to TR in the area between the reference landmarks. Most of the evaluated resin/3D printer combinations suffered significant dimensional alterations after autoclaving.
dc.format.extent13 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec760199
dc.identifier.issn2079-4983
dc.identifier.pmid40863304
dc.identifier.urihttps://hdl.handle.net/2445/223109
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/jfb16080284
dc.relation.ispartofJournal of Functional Biomaterials, 2025, vol. 16, num.8, p. 284-284
dc.relation.urihttps://doi.org/10.3390/jfb16080284
dc.rightscc-by (c) González-Barnadas, A. et al., 2025
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationImpressió 3D
dc.subject.classificationOdontologia estètica
dc.subject.classificationCirurgia oral
dc.subject.otherThree-dimensional printing
dc.subject.otherDental aesthetic
dc.subject.otherOral surgery
dc.titleImpact of autoclaving on the dimensional stability of 3D-Printed surgical guides for aesthetic crown lengthening
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
898900.pdf
Mida:
1.27 MB
Format:
Adobe Portable Document Format

Paquet de llicències

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
license.txt
Mida:
1.71 KB
Format:
Item-specific license agreed upon to submission
Descripció: