An optimized immunohistochemistry technique improves NMO-IgG detection: study comparison with cell-based assays

dc.contributor.authorHöftberger, Romana
dc.contributor.authorSabater Baudet, Lidia
dc.contributor.authorMarignier, Romain
dc.contributor.authorAboul-Enein, Fahmy
dc.contributor.authorBernard-Valnet, Raphaël
dc.contributor.authorRauschka, Helmut
dc.contributor.authorRuiz, Anne
dc.contributor.authorBlanco Morgado, Yolanda
dc.contributor.authorGraus Ribas, Francesc
dc.contributor.authorDalmau Obrador, Josep
dc.contributor.authorSaiz Hinarejos, Albert
dc.date.accessioned2018-07-24T12:57:29Z
dc.date.available2018-07-24T12:57:29Z
dc.date.issued2013-11-04
dc.date.updated2018-07-24T12:57:29Z
dc.description.abstractCell-based assays (CBA) have increased the sensitivity of the neuromyelitis optica (NMO)-IgG/aquaporin-4-antibody detection compared to classical tissue-based indirect assays. We describe the sensitivity of an optimized immunohistochemistry (IHC-o) to detect NMO-IgG/aquaporin-4-antibody in comparison with that of two CBA: an in-house (CBA-ih) and a commercial (CBA-c) assay (Euroimmun, Germany). Coded serum from 103 patients with definite NMO and 122 inflammatory controls were studied by IHC-o, CBA-ih, and CBA-c. IHC-o used the same protocol described to detect antibodies against cell surface antigens. CBA-ih used live cells transfected with the aquaporin-4-M23-isoform. The sensitivity of the IHC-o was 74.8% (95% confidence interval [CI] 65-83) and was similar to that of the CBA-ih 75.7% (95% CI 66-84) and the CBA-c 73.8% (95% CI 64-82). The specificity of the three assays was 100% (95% CI 97-100). Interassay concordance was high, 100 of 103 samples were coincident in all techniques. The optimized immunohistochemistry proves to be as sensitive and specific as the cell-based assays. This assay extends the available tools for NMO-IgG/aquaporin-4-antibody detection.
dc.format.extent6 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec654344
dc.identifier.issn1932-6203
dc.identifier.pmid24223884
dc.identifier.urihttps://hdl.handle.net/2445/123874
dc.language.isoeng
dc.publisherPublic Library of Science (PLoS)
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1371/journal.pone.0079083
dc.relation.ispartofPLoS One, 2013, vol. 8, num. 11, p. 1-6
dc.relation.urihttps://doi.org/10.1371/journal.pone.0079083
dc.rightscc-by (c) Höftberger, Romana et al., 2013
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationImmunohistoquímica
dc.subject.classificationImmunoglobulines
dc.subject.otherImmunohistochemistry
dc.subject.otherImmunoglobulins
dc.titleAn optimized immunohistochemistry technique improves NMO-IgG detection: study comparison with cell-based assays
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
654344.pdf
Mida:
787.77 KB
Format:
Adobe Portable Document Format