Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Published version

Publication date

Publication license

cc-by (c) Vergara, Andrea et al., 2020
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/150965

Assessment of a Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Pathogenic Bacteria from Respiratory Samples in Patients with Hospital-Acquired Pneumonia

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

Rapid identification of the causative agent of hospital-acquired pneumonia (HAP) will allowan earlier administration of a more appropriate antibiotic and could improve the outcome of thesepatients. The aim of this study was to develop a rapid protocol to identify the main microorganismsinvolved in HAP by loop-mediated isothermal amplification (LAMP) directly from respiratory samples.First of all, a rapid procedure (<30 min) to extract the DNA from bronchoalveolar lavage (BAL),endotracheal aspirate (EA) or bronchoaspirate (BAS) was set up. A specific LAMP forStaphylococcusaureus,Escherichia coli,Klebsiella pneumoniae, Pseudomonas aeruginosa,Stenotrophomonas maltophiliaandAcinetobacter baumanniiwas performed with the extracted solution at 65◦C for 30-40 min. Overall,58 positive BAL and 83 EA/BAS samples were tested. The limits of detection varied according to themicroorganism detected. Validation of the LAMP assay with BAL samples showed that the assay was 100% specific and 86.3% sensitive (positive predictive value of 100% and a negative predictive valueof 50%) compared with culture. Meanwhile for BAS/EA samples, the assay rendered the followingstatistical parameters: 100% specificity, 94.6% sensitivity, 100% positive predictive value and 69.2%negative predictive value. The turnaround time including sample preparation and LAMP was circa1 h. LAMP method may be used to detect the most frequent bacteria causing HAP. It is a simple,cheap, sensitive, specific and rapid assay.

Citation

Citation

VERGARA GÓMEZ, Andrea, et al. Assessment of a Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Pathogenic Bacteria from Respiratory Samples in Patients with Hospital-Acquired Pneumonia. Microorganisms. 2020. Vol. 8, num. 1, pags. 103. ISSN 2076-2607. [consulted: 13 of August of 2026]. Available at: https://hdl.handle.net/2445/150965

Export metadata

JSON - METS

Share record