Carregant...
Tipus de document
ArticleVersió
Versió publicadaData de publicació
Llicència de publicació
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/117626
Interferon-gamma-Inducible Protein 10 (IP-10) as a Screening Tool to Optimize Human Immunodeficiency Virus RNA Monitoring in Resource-Limited Settings
Títol de la revista
Director/Tutor
ISSN de la revista
Títol del volum
Recurs relacionat
Resum
Background: Achieving effective antiretroviral treatment (ART)
monitoring is a key determinant to ensure viral suppression and
reach the UNAIDS 90-90-90 targets. The gold standard for
detecting virological failure is plasma human immunodeficiency
virus (HIV) RNA (viral load [VL]) testing; however, its
availability is very limited in low-income countries due to cost
and operational constraints. Methods: HIV-1-infected adults on
first-line ART attending routine visits at the Manhica District
Hospital, Mozambique, were previously evaluated for virologic
failure. Plasma levels of interferon-gamma-inducible protein 10
(IP-10) were quantified by enzyme-linked immunosorbent assay.
Logistic regression was used to build an IP-10-based model able
to identify individuals with VL >150 copies/mL. From the 316
individuals analyzed, 253 (80%) were used for model training and
63 (20%) for validation. Receiver operating characteristic
curves were employed to evaluate model prediction. Results: From
the individuals included in the training set, 34% had detectable
VL. Mean age was 41 years, 70% were females, and median time on
ART was 3.4 years. IP-10 levels were significantly higher in
subjects with detectable VL (108.2 pg/mL) as compared to those
with undetectable VL (38.0 pg/mL) (P < .0001, U test). IP-10
univariate model demonstrated high classification performance
(area under the curve = 0.85 [95% confidence interval {CI},
.80-.90]). Using a cutoff value of IP-10 >/=44.2 pg/mL, the
model identified detectable VL with 91.9% sensitivity (95% CI,
83.9%-96.7%) and 59.9% specificity (95% CI, 52.0%-67.4%), values
confirmed in the validation set. Conclusions: IP-10 is an
accurate biomarker to screen individuals on ART for detectable
viremia. Further studies should evaluate the benefits of IP-10
as a triage approach to monitor ART in resource-limited
settings.
Matèries
Matèries (anglès)
Citació
Col·leccions
Citació
PASTOR, Lucía, CASELLAS, Aina, RUPÉREZ, María, CARRILLO MOLINA, Jorge, MACULUVE, Sónia amós, JAIROCE, Chenjerai tobias sixpence, PAREDES, Roger, BLANCO, Julià, NANICHE, Denise. Interferon-gamma-Inducible Protein 10 (IP-10) as a Screening
Tool to Optimize Human Immunodeficiency Virus RNA Monitoring in
Resource-Limited Settings. _Clinical Infectious Diseases_. 2017. Vol. 65, núm. 10, pàgs. 1670-1675. [consulta: 9 de gener de 2026]. ISSN: 1058-4838. [Disponible a: https://hdl.handle.net/2445/117626]