Evaluación y gestión del riesgo asociado a la reutilización de aguas residuales

dc.contributor.advisorFolch Sánchez, Montserrat
dc.contributor.advisorTapias Pantebre, Josefina Carlota
dc.contributor.authorAlcalde Sanz, Laura
dc.contributor.otherUniversitat de Barcelona. Departament de Productes Naturals, Biologia Vegetal i Edafologia
dc.date.accessioned2013-05-07T08:48:52Z
dc.date.available2013-05-07T08:48:52Z
dc.date.issued2012-06-15
dc.description.abstract[spa] La reutilización de aguas residuales comporta una serie de beneficios pero también conlleva un riesgo asociado a nivel sanitario y medioambiental debido a los componentes que puedan estar presentes en el agua residual, como microorganismos patógenos y contaminantes químicos tóxicos. Este riesgo asociado se ha de controlar para poder reutilizar el agua de la manera más segura posible. En este trabajo se evaluó la efectividad de diferentes tecnologías de regeneración (infiltración-percolación, fisicoquímico, filtro de anillas, dióxido de cloro, ácido peracético y radiación ultravioleta) y se establecieron las líneas de tratamiento más adecuadas para cumplir con los criterios de calidad establecidos por el RD 1620/2007 sobre reutilización de aguas residuales. También se evaluó un sistema de reutilización utilizado para el riego de un parque, considerando la EDAR, la ERA, el sistema de almacenamiento y la red de distribución hasta el punto de uso final del agua regenerada. Se estableció el comportamiento de diferentes parámetros microbiológicos y fisicoquímicos en cada etapa y las variaciones de calidad del agua regenerada a su paso por el sistema. Se realizó una evaluación cuantitativa del riesgo microbiológico (QMRA) asociado al riego del parque con agua regenerada, utilizando los patógenos de referencia de la OMS (Campylobacter, rotavirus y Cryptosporidium), concluyendo que el nivel de riesgo cumple con el nivel aceptable establecido. También se evaluó la influencia del riego con agua regenerada en las matrices ambientales suelo y agua subterránea, concluyéndose que, en el espacio de tiempo evaluado, no se aprecia una variación de la calidad fisicoquímica de estas matrices debido al riego. Por último, se aplicó un protocolo de análisis de peligros y puntos de control críticos (APPCC) en el sistema de reutilización, tal y como recomienda la OMS para gestionar el riesgo asociado a la reutilización de aguas. La aplicación de este protocolo permitió identificar los puntos de control críticos del sistema, recomendar límites críticos para cada punto y establecer medidas correctoras para las posibles desviaciones de estos límites.spa
dc.description.abstract[eng] Wastewater reuse provides an additional source of water resources, but there is a health and environmental risk associated with the use of reclaimed water, due to the potential presence of pathogens and toxic chemicals. These risks have to be controlled in order to be able to use reclaimed water in a safety way. In this work, several reclamation technologies have been evaluated (infiltration-percolation, physicochemical, chlorine dioxide, peracetic acid and ultraviolet radiation) to establish treatment lines that comply with the quality criteria of the national regulation RD 1620/2007 on wastewater reuse. A reuse system for the irrigation of a green area was evaluated, including the WWTP, the RWTP, the storage system and the distribution system to the irrigation place. Several microbial organisms and physicochemical parameters were monitored in each component to evaluate the variations on the reclaimed water along the system. A quantitative microbiological risk assessment (QMRA) was performed, using a computer model, in order to evaluate the risk associated to the green area irrigation, considering the three pathogens recommended by the WHO (Campylobacter, rotavirus and Cryptosporidium), resulting on the risk level complying with the acceptable level established. The environmental matrixes soil and groundwater were evaluated to determine any variation in the physicochemical quality due to the irrigation with reclaimed water, concluding that, for the time period of the study, there is not a significant variation. A hazard analysis and critical control point protocol was applied to the reuse system evaluated, as recommended by the WHO for risk management in water reuse. This protocol allowed establishing the critical control points of the system, the critical limits for each point and the corrective measures in case of deviation from the operational parameters.eng
dc.format.extent258 p.
dc.format.mimetypeapplication/pdf
dc.identifier.dlB. 21745-2012
dc.identifier.tdxhttp://hdl.handle.net/10803/82147
dc.identifier.urihttps://hdl.handle.net/2445/42692
dc.language.isospa
dc.publisherUniversitat de Barcelona
dc.rights(c) Alcalde Sanz, 2012
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceTesis Doctorals - Departament - Productes Naturals, Biologia Vegetal i Edafologia
dc.subject.classificationReutilització de l'aigua
dc.subject.classificationDepuració d'aigües residuals
dc.subject.classificationAvaluació del risc per la salut
dc.subject.otherWater reuse
dc.subject.otherPurification of sewage
dc.subject.otherHealth risk assessment
dc.titleEvaluación y gestión del riesgo asociado a la reutilización de aguas residualesspa
dc.typeinfo:eu-repo/semantics/doctoralThesis
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
LAURA_ALCALDE_TESIS.pdf
Mida:
3.46 MB
Format:
Adobe Portable Document Format