Impact of left atrial volume, sphericity, and fibrosis on the outcome of catheter ablation for atrial fibrillation
| dc.contributor.author | den Uijl, Dennis W. | |
| dc.contributor.author | Cabanelas, Nuno | |
| dc.contributor.author | Benito, Eva | |
| dc.contributor.author | Figueras, Rosa | |
| dc.contributor.author | Alarcón, Francisco | |
| dc.contributor.author | Borràs, Roger | |
| dc.contributor.author | Prat González, Susanna | |
| dc.contributor.author | Guasch i Casany, Eduard | |
| dc.contributor.author | Perea Palazón, Rosario Jesús | |
| dc.contributor.author | Sitges Carreño, Marta | |
| dc.contributor.author | Brugada Terradellas, Josep, 1958- | |
| dc.contributor.author | Berruezo Sánchez, Antonio | |
| dc.contributor.author | Mont Girbau, Lluís | |
| dc.date.accessioned | 2019-11-26T10:04:39Z | |
| dc.date.available | 2019-11-26T10:04:39Z | |
| dc.date.issued | 2018-03-12 | |
| dc.date.updated | 2019-11-26T10:04:39Z | |
| dc.description.abstract | INTRODUCTION: To investigate the relation between left atrial (LA) volume, sphericity, and fibrotic content derived from contrast-enhanced cardiac magnetic resonance imaging (CE-CMR) and their impact on the outcome of catheter ablation for atrial fibrillation (AF). METHODS AND RESULTS: In 83 patients undergoing catheter ablation for AF, CE-CMR was used to assess LA volume, sphericity, and fibrosis. There was a significant correlation between LA volume and sphericity (R = 0.535, P < 0.001) and between LA volume and fibrosis (R = 0.241, P = 0.029). Multivariate analyses demonstrated that LA volume was the strongest independent predictor of AF recurrence after catheter ablation (1.019, P = 0.018). CONCLUSION: LA volume, sphericity, and fibrosis were closely related; however, LA volume was the strongest predictor of AF recurrence after catheter ablation. | |
| dc.format.extent | 23 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 680204 | |
| dc.identifier.issn | 1045-3873 | |
| dc.identifier.uri | https://hdl.handle.net/2445/145401 | |
| dc.language.iso | eng | |
| dc.publisher | Wiley | |
| dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1111/jce.13482 | |
| dc.relation.ispartof | Journal of Cardiovascular Electrophysiology, 2018, vol. 29, num. 5, p. 740-746 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/EC/H2020/633196/EU//CATCH ME | |
| dc.relation.uri | https://doi.org/10.1111/jce.13482 | |
| dc.rights | (c) Wiley, 2018 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.source | Articles publicats en revistes (Medicina) | |
| dc.subject.classification | Fibril·lació auricular | |
| dc.subject.classification | Arrítmia | |
| dc.subject.classification | Ressonància magnètica | |
| dc.subject.other | Atrial fibrillation | |
| dc.subject.other | Arrhythmia | |
| dc.subject.other | Magnetic resonance | |
| dc.title | Impact of left atrial volume, sphericity, and fibrosis on the outcome of catheter ablation for atrial fibrillation | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/acceptedVersion |
Fitxers
Paquet original
1 - 1 de 1