Radiation Exposure in Endovascular Surgery According to Complexity: Protocol for a Prospective Observational Study

dc.contributor.authorMartínez del Carmen, Dorelly Tanayra
dc.contributor.authorSaldaña Gutiérrez, Pablo
dc.contributor.authorVila Coll, Ramón
dc.contributor.authorIborra Ortega, Elena
dc.date.accessioned2023-07-25T11:18:54Z
dc.date.available2023-07-25T11:18:54Z
dc.date.issued2023-05-10
dc.date.updated2023-07-13T08:46:08Z
dc.description.abstractIn the past decades, we have witnessed tremendous developments in endovascular surgery. Nowadays, highly complex procedures are performed by minimally invasive means. A key point is equipment improvement. Modern C-arms provide advanced imaging capabilities, facilitating endovascular navigation with an adequate open surgical environment. Nevertheless, radiation exposure remains an issue of concern. This study aims to analyze radiation used during endovascular procedures according to complexity, comparing a mobile X-ray system with a hybrid room (fixed X-ray system). This is an observational and prospective study based on a cohort of non-randomized patients treated by endovascular procedures in a Vascular Surgery department using two imaging systems. The study is planned for a 3-year duration with a recruitment period of 30 months (beginning 20 July 2021) and a 1-month follow-up period for each patient. This is the first prospective study designed to describe the radiation dose according to the complexity of the procedure. Another strength of this study is that radiologic variables are obtained directly from the C-arm and no additional measurements are required for feasibility benefit. The results from this study will help us determine the level of radiation in different endovascular procedures, in view of their complexity.
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.issn2409-9279
dc.identifier.pmid37218909
dc.identifier.urihttps://hdl.handle.net/2445/201171
dc.language.isoeng
dc.publisherMDPI AG
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/mps6030049
dc.relation.ispartofMethods and Protocols, 2023, vol. 6, num. 3
dc.relation.urihttps://doi.org/10.3390/mps6030049
dc.rightscc by (c) Martínez del Carmen, Dorelly Tanayra et al, 2023
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationCirurgia cardiovascular
dc.subject.classificationDosimetria (Radiació)
dc.subject.otherCardiovascular surgery
dc.subject.otherRadiation dosimetry
dc.titleRadiation Exposure in Endovascular Surgery According to Complexity: Protocol for a Prospective Observational Study
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
mps-06-00049-v2.pdf
Mida:
255.78 KB
Format:
Adobe Portable Document Format