Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc by (c) Bello Gil, Daniel et al., 2026
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/230038

Humoral immune responses to hyaluronan oligosaccharides in patients undergoing prosthetic valve surgery

Títol de la revista

Director/Tutor

Contribució addicional

ISSN de la revista

Títol del volum

Resum

Background Bioprosthetic heart valves (BHVs) are widely used in cardiac surgery but are limited by structural valve deterioration (SVD). The Translink study showed that immune responses to xenogeneic glycans contribute to SVD. Hyaluronan (HA), a glycosaminoglycan with size-dependent biological functions, has been implicated in inflammation, xenoreactivity, and valve calcification. This study investigated humoral immune responses to HA oligosaccharides in a subgroup of the Translink cohort.Patients and methods Serum samples from 258 BHV recipients and 78 cardiac surgery controls were analyzed by ELISA, and a representative subset was further profiled using a printed glycan array (PGA). BHV recipients were classified with clinically significant SVD (A), as de novo implantation (B1), or long-term without SVD (B2). Controls included mechanical valve replacement or coronary artery bypass patients, either de novo (B1C) or long-term post-surgery (B2C). ELISA quantified IgG and IgM antibodies against HA fragments of increasing length (HA2, HA24, HA84), while PGA mapped fine specificity across HA2-HA40.Results All subjects exhibited measurable baseline anti-HA IgG and IgM antibodies. ELISA revealed a fragment-length dependence, with the shortest fragment, HA2, showing the highest antibody binding, and progressively lower reactivity with longer oligomers. Following de novo cardiac surgery, both BHV recipients and controls showed a transient increase in anti-HA antibodies, peaking at one month and declining within 6-12 months. In contrast, PGA consistently identified HA34 as the dominant immunogenic fragment across all cohorts and time points.Conclusions Anti-HA antibodies are constitutively present in humans, undergo transient amplification after cardiac surgery, regardless of prosthesis type, and display marked fragment-length specificity. Short HA2 fragments predominate in ELISA responses, whereas intermediate-length oligomers, such as HA34, emerge as conserved, immunodominant targets in PGA. These findings extend the Translink paradigm from xenogeneic to matrix-derived glycan immunity and identify anti-HA antibodies as potential biomarkers of postoperative inflammation and tissue remodeling, which could be relevant to SVD.

Matèries (anglès)

Citació

Citació

BELLO GIL, Daniel, et al. Humoral immune responses to hyaluronan oligosaccharides in patients undergoing prosthetic valve surgery. Frontiers in Immunology. 2026. Vol. 17. ISSN 1664-3224. [consulted: 27 of November of 2026]. Available at: https://hdl.handle.net/2445/230038

Exportar metadades

JSON - METS

Compartir registre