Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Colour perception screening and shade-matching performance among undergraduate dental students: an exploratory observational study

dc.contributor.authorTorné Duran, Sergi
dc.date.accessioned2026-07-28T07:30:10Z
dc.date.available2026-07-28T07:30:10Z
dc.date.issued2026-07-14
dc.date.updated2026-07-28T07:30:11Z
dc.description.abstractBackground: Visual shade selection remains widely used in restorative and prosthetic dentistry and is influenced by interobserver variability, illumination conditions, and individual visual factors. However, the relationship between colour perception screening findings and shade-matching performance in undergraduate dental students remains insufficiently explored. Objective: To assess colour perception screening findings and shade-matching performance among undergraduate dental students using the Ishihara test and practical shade-selection tasks. Methods: An exploratory cross-sectional study was conducted including 80 fourth- and fifth-year dental students enroled in the prosthodontics course at the University of Barcelona during the 2017–2018 academic year. Colour perception was screened using the Ishihara 24-plate test. Shade-matching performance was evaluated through two practical tasks: pairing corresponding tabs from two Chromascop shade guides and selecting the reference shade of a ceramic crown. Incorrect responses, shade-selection discrepancies, and completion time were recorded. Statistical analysis included descriptive statistics and bivariate tests selected according to the type of variable and expected cell frequencies. Results: Eighty students participated in the study (33.75% male, 66.25% female). Ishihara screening findings compatible with colour vision deficiency were observed in 2.5% of participants, while isolated incorrect plate responses were observed in a larger proportion of students. Shade-matching discrepancies were frequent in both practical tasks. Self-reported ophthalmological conditions were associated with a higher number of shade-selection discrepancies (p < 0.05). Longer completion times tended to be associated with more discrepancies, although this association was not statistically significant. No significant differences were observed according to sex. Conclusions: Within the limitations of this exploratory study, shade-matching discrepancies were common among undergraduate dental students and were not limited to participants with Ishihara screening findings compatible with colour vision deficiency. These findings support the relevance of structured training in colour science and shade selection during prosthodontic education. Further studies using standardized perceptual and instrumental reference methods are needed.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec771169
dc.identifier.pmid42448651
dc.identifier.urihttps://hdl.handle.net/2445/231052
dc.language.isoeng
dc.publisherSpringer Nature
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1038/s41405-026-00454-9
dc.relation.ispartofBDJ Open, 2026, vol. 12
dc.relation.urihttps://doi.org/10.1038/s41405-026-00454-9
dc.rightscc-by-nc-nd (c) Torné-Durán, Sergi, 2026
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationVisió cromàtica
dc.subject.classificationProstodòncia
dc.subject.otherColor vision
dc.subject.otherProsthodontics
dc.titleColour perception screening and shade-matching performance among undergraduate dental students: an exploratory observational study
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
940923.pdf
Mida:
969.77 KB
Format:
Adobe Portable Document Format