Effect of expiratory flow limitation on respiratory mechanical impedance: a model study

dc.contributor.authorPeslin, Renécat
dc.contributor.authorFarré Ventura, Ramoncat
dc.contributor.authorRotger i Estapé, Maria del Marcat
dc.contributor.authorNavajas Navarro, Danielcat
dc.date.accessioned2012-05-16T10:17:10Z
dc.date.available2012-05-16T10:17:10Z
dc.date.issued1996
dc.description.abstractLarge phasic variations of respiratory mechanical impedance (Zrs) have been observed during induced expiratory flow limitation (EFL) (M. Vassiliou, R. Peslin, C. Saunier, and C. Duvivier. Eur. Respir. J. 9: 779-786, 1996). To clarify the meaning of Zrs during EFL, we have measured from 5 to 30 Hz the input impedance (Zin) of mechanical analogues of the respiratory system, including flow-limiting elements (FLE) made of easily collapsible rubber tubing. The pressures upstream (Pus) and downstream (Pds) from the FLE were controlled and systematically varied. Maximal flow (Vmax) increased linearly with Pus, was close to the value predicted from wave-speed theory, and was obtained for Pus-Pds of 4-6 hPa. The real part of Zin started increasing abruptly with flow (V) >85%Vmax and either further increased or suddenly decreased in the vicinity of V¿max. The imaginary part of Zin decreased markedly and suddenly above 95%Vmax. Similar variations of Zin during EFL were seen with an analogue that mimicked the changes of airway transmural pressure during breathing. After pressure andV measurements upstream and downstream from the FLE were combined, the latter was analyzed in terms of a serial (Zs) and a shunt (Zp) compartment. Zs was consistent with a large resistance and inertance, and Zp with a mainly elastic element having an elastance close to that of the tube walls. We conclude that Zrs data during EFL mainly reflect the properties of the FLE.eng
dc.format.extent8 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec117348
dc.identifier.issn8750-7587
dc.identifier.urihttps://hdl.handle.net/2445/25845
dc.language.isoengeng
dc.publisherThe American Physiological Society
dc.relation.isformatofReproducció del document publicat a: http://intl-jap.physiology.org/content/81/6/2399
dc.relation.ispartofJournal of Applied Physiology, 1996, vol. 81, num. 6, p. 2399-2406
dc.rights(c) The American Physiological Society, 1996
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Ciències Fisiològiques)
dc.subject.classificationRespiraciócat
dc.subject.classificationPulmócat
dc.subject.classificationModels biològicscat
dc.subject.otherRespirationeng
dc.subject.otherLungeng
dc.subject.otherBiological modelseng
dc.titleEffect of expiratory flow limitation on respiratory mechanical impedance: a model studyeng
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
117348.pdf
Mida:
118.03 KB
Format:
Adobe Portable Document Format