Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Published version

Publication date

Publication license

cc by (c) Alegret et al., 2012
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/126520

Trends in the use of electrical cardioversion for atrial fibrillation: influence of major trials and guidelines on clinical practice

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

Background: The purpose of the present study was to assess the trends in the use of ECV following published studies that had compared rhythm and rate control strategies on atrial fibrillation (AF), and the recommendations included in the current clinical practice guidelines. Methods: The REVERCAT is a population-based assessment of the use of electrical cardioversion (ECV) in treating persistent AF in Catalonia (Spain). The initial survey was conducted in 2003 and the follow-up in 2010. Results: We observed a decrease of 9% in the absolute numbers of ECV performed (436 in 2003 vs. 397 in 2010). This is equivalent to 27% when considering population increases over this period. The patients treated with ECV in 2010 were younger, had a lower prevalence of previous embolism, a higher prevalence of diabetes, and increased body weight. Underlying heart disease factors indicated, in 2010, a higher proportion of NYHA >= II and left ventricular ejection fraction <30%. We observed a reduction in the number of ECV performed in 16 of the 27 (67%) participating hospitals. However, there was an increase of 14% in the number of procedures performed in tertiary hospitals, and was related to the increasing use of ECV as a bridge to AF ablation. Considering the initial number of patients treated with ECV, the rate of sinus rhythm at 3 months was almost unchanged (58% in 2003 vs. 57% in 2010; p = 0.9) despite the greater use of biphasic energy in 2010 and a similar prescription of anti-arrhythmic drugs. Conclusions: Although we observed a decrease in the number of ECVs performed over the 7 year period between the two studies, this technique remains a common option for treating patients with persistent AF. The change in the characteristics of candidate patients did not translate into better outcomes.

Citation

Citation

ALEGRET, Josep M., et al. Trends in the use of electrical cardioversion for atrial fibrillation: influence of major trials and guidelines on clinical practice. BMC Cardiovascular Disorders. 2012. Vol. 12, num. 42. [consulted: 11 of August of 2026]. Available at: https://hdl.handle.net/2445/126520

Export metadata

JSON - METS

Share record