Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc by (c) Jiménez Martínez, Emilio et al, 2023
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/214881

Peripheral intravenous catheter failure, nurse staffing levels and care complexity individual factors: A retrospective multicentre cohort study

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Introduction Short peripheral intravenous catheter (PIVC) failure is a common complication that is generally underdiagnosed. Some studies have evaluated the factors associated with these complications, but the impact of care complexity individual factors and nurse staffing levels on PIVC failure is still to be assessed. The aim of this study was to determine the incidence and risk factors of PIVC failure in the public hospital system of the Southern Barcelona Metropolitan Area.Methods A retrospective multicentre observational cohort study of hospitalised adult patients was conducted in two public hospitals in Barcelona from 1st January 2016 to 31st December 2017. All adult patients admitted to the hospitalisation ward were included until the day of discharge. Patients were classified according to presence or absence of PIVC failure. The main outcomes were nurse staffing coverage (ATIC patient classification system) and 27-care complexity individual factors. Data were obtained from electronic health records in 2022.Results Of the 44,661 patients with a PIVC, catheter failure was recorded in 2,624 (5.9%) patients (2,577 [5.8%] phlebitis and 55 [0.1%] extravasation). PIVC failure was more frequent in female patients (42%), admitted to medical wards, unscheduled admissions, longer catheter dwell time (median 7.3 vs 2.2 days) and those with lower levels of nurse staffing coverage (mean 60.2 vs 71.5). Multivariate logistic regression analysis revealed that the female gender, medical ward admission, catheter dwell time, haemodynamic instability, uncontrolled pain, communication disorders, a high risk of haemorrhage, mental impairments, and a lack of caregiver support were independent factors associated with PIVC failure. Moreover, higher nurse staffing were a protective factor against PIVC failure (AUC, 0.73; 95% confidence interval [CI]: 0.72-0.74).Conclusion About 6% of patients presented PIVC failure during hospitalisation. Several complexity factors were associated with PIVC failure and lower nurse staffing levels were identified in patients with PIVC failure. Institutions should consider that prior identification of care complexity individual factors and nurse staffing coverage could be associated with a reduced risk of PIVC failure.

Citació

Citació

JIMÉNEZ MARTÍNEZ, Emilio, ADAMUZ, Jordi, GONZÁLEZ SAMARTINO, Maribel, MUÑOZ CARMONA, Maria antonia, HORNERO, Ana, MARTOS MARTÍNEZ, M. purificacion, MEMBRIVE MARTÍNEZ, Remedios, JUVÉ UDINA, María eulàlia. Peripheral intravenous catheter failure, nurse staffing levels and care complexity individual factors: A retrospective multicentre cohort study. _PLOS ONE_. 2024. Vol. 19, núm. 5. [consulta: 21 de gener de 2026]. ISSN: 1932-6203. [Disponible a: https://hdl.handle.net/2445/214881]

Exportar metadades

JSON - METS