Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Doctoral thesis

Version

Published version

Publication date

All rights reserved

Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/41806

Momentum measurements of single-beam traps and quantitative holographic experiments: two sides of the same coin

Journal Title

Journal ISSN

Volume Title

Related resource

Abstract

After an intense development of optical tweezers as a biophysical tool during the last decades, quantitative experiments in living cells have not found in this technique its best ally, due, in part, to the lack of a reliable method to measure forces in complex environments. The attempts to overcome this problem either require complicated in situ calibrations, which make their use impossible in the study of dynamic processes, or they are inaccurate. Using a different approach, Steven Smith at Carlos Bustamante’s lab at the University of Berkeley developed a method based on the direct measurement of the momentum change of the trapping beam. However, its diffusion has been modest mainly because it requires a counter-propagating optical trapping system, which is difficult to implement and combine with other techniques. Although it has not been used for this purpose yet, it seems a more suitable method for in vivo experiments since the measurement depends only on some properties of the sensor apparatus but not on the experiment itself. On the other hand, the use of holographic optical tweezers in molecular biology experiments involving force and position measurements is still far from established. The existence of different effects associated to the use of spatial light modulators to create the optical traps has restricted their use. In this thesis, I present the work that I carried out in the Optical Trapping Lab – Grup de Biofotònica at the University of Barcelona related to these two subjects. During these years, I have focused on the implementation of the force detection method based on the conservation of the light momentum in single-beam optical traps, and on the analysis of several aspects of holographic tweezers oriented to their use in quantitative experiments.

Subject (English)

Citation

Citation

FARRÉ FLAQUER, Arnau. Momentum measurements of single-beam traps and quantitative holographic experiments: two sides of the same coin. [consulted: 16 of August of 2026]. Available at: https://hdl.handle.net/2445/41806

Export metadata

JSON - METS

Share record