Arthroscopic All-Inside Remplissage Technique With Knotless Tape Bridge for Hill-Sachs Lesions

dc.contributor.authorHachem, Abdul Ilah
dc.contributor.authorMolina Creixell, Andrés
dc.contributor.authorRondanelli S., Rafael
dc.contributor.authorValero Cifuentes, Gregorio
dc.contributor.authorCampagnoli, Alex
dc.contributor.authorHermida, Miguel
dc.contributor.authorRius, Xavier
dc.date.accessioned2024-03-26T19:42:15Z
dc.date.available2024-03-26T19:42:15Z
dc.date.issued2023-09-01
dc.date.updated2023-10-31T09:25:16Z
dc.description.abstractThe arthroscopic remplissage procedure has been described to successfully treat engaging Hill-Sachs lesions and improve shoulder stability. Several variations of this technique have been described, including remplissage with 1 or 2 knotted or knotless anchors, remplissage with double or triple bridging pulleys, and remplissage with or without a subacromial view. However, most techniques use anchors in combination with round sutures. This article describes an allarthroscopic articular knotless remplissage technique using a strong, flat, double-strand suture tape bridge fixed with 2 small anchors under direct joint visualization and reduction of the capsule and infraspinatus without requiring a subacromial view.
dc.format.extent8 p.
dc.format.mimetypeapplication/pdf
dc.identifier.issn2212-6287
dc.identifier.pmid37780647
dc.identifier.urihttps://hdl.handle.net/2445/209247
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.eats.2023.04.021
dc.relation.ispartofArthroscopy Techniques, 2023, vol. 12, num. 9, p. e1487-e1494
dc.relation.urihttps://doi.org/10.1016/j.eats.2023.04.021
dc.rightscc by-nc-nd (c) Hachem, Abdul Ilah et al., 2023
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationLuxacions
dc.subject.classificationHúmer
dc.subject.classificationArtroscòpia
dc.subject.otherDislocations
dc.subject.otherHumerus
dc.subject.otherArthroscopy
dc.titleArthroscopic All-Inside Remplissage Technique With Knotless Tape Bridge for Hill-Sachs Lesions
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
PIIS2212628723001299.pdf
Mida:
2.2 MB
Format:
Adobe Portable Document Format