Efficacy and safety of the Clearum dialyzer

dc.contributor.authorMaduell, Francisco
dc.contributor.authorBroseta, José Jesús
dc.contributor.authorRodríguez Espinosa, Diana
dc.contributor.authorHermida, Evelyn
dc.contributor.authorCuadrado Payán, Elena
dc.contributor.authorRodas, Lida M.
dc.contributor.authorGómez, Miquel
dc.contributor.authorArias Guillén, Marta
dc.contributor.authorFontseré, Néstor
dc.contributor.authorVera, Manel
dc.contributor.authorRico, Nayra
dc.date.accessioned2026-06-18T07:20:40Z
dc.date.available2026-06-18T07:20:40Z
dc.date.issued2021-05-12
dc.date.updated2026-06-18T07:20:41Z
dc.description.abstractThe Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec724734
dc.identifier.issn0160-564X
dc.identifier.pmid33978975
dc.identifier.urihttps://hdl.handle.net/2445/230093
dc.language.isoeng
dc.publisherBlackwell Science
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1111/aor.13993
dc.relation.ispartofArtificial Organs, 2021, vol. 45, num.10, p. 1195-1201
dc.relation.urihttps://doi.org/10.1111/aor.13993
dc.rightscc-by-nc-nd (c) Maduell, Francisco et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationPesos moleculars
dc.subject.classificationTelemàtica
dc.subject.classificationTelemàtica mèdica
dc.subject.otherMolecular weights
dc.subject.otherTelematics
dc.subject.otherMedical telematics
dc.titleEfficacy and safety of the Clearum dialyzer
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1