Minimizing acquisition-related radiomics variability by image resampling and batch effect correction to allow for large-scale data analysis

dc.contributor.authorLigero Hernández, Marta
dc.contributor.authorJordi Ollero, Olivia
dc.contributor.authorBernatowicz, Kinga
dc.contributor.authorGarcia Ruiz, Alonso
dc.contributor.authorDelgado Muñoz, Eric
dc.contributor.authorLeiva Pedraza, David
dc.contributor.authorMast, Richard
dc.contributor.authorSuarez, Cristina
dc.contributor.authorSala Llonch, Roser
dc.contributor.authorCalvo, Nahum
dc.contributor.authorEscobar, Manuel
dc.contributor.authorNavarro Martín, Arturo
dc.contributor.authorVillacampa, Guillermo
dc.contributor.authorDienstmann, Rodrigo
dc.contributor.authorPérez López, Raquel
dc.date.accessioned2021-04-22T13:20:43Z
dc.date.available2021-04-22T13:20:43Z
dc.date.issued2020-09-09
dc.date.updated2021-04-22T13:20:43Z
dc.description.abstractObjective: To identify CT-acquisition parameters accounting for radiomics variability and to develop a post-acquisition CTimage correction method to reduce variability and improve radiomics classification in both phantom and clinical applications. Methods: CT-acquisition protocols were prospectively tested in a phantom. The multi-centric retrospective clinical study included CT scans of patients with colorectal/renal cancer liver metastases. Ninety-three radiomics features of first order and texture were extracted. Intraclass correlation coefficients (ICCs) between CT-acquisition protocols were evaluated to define sources of variability. Voxel size, ComBat, and singular value decomposition (SVD) compensation methods were explored for reducing the radiomics variability. The number of robust features was compared before and after correction using two-proportion z test. The radiomics classification accuracy (K-means purity) was assessed before and after ComBat- and SVD-based correction. Results: Fifty-three acquisition protocols in 13 tissue densities were analyzed. Ninety-seven liver metastases from 43 patients with CT from two vendors were included. Pixel size, reconstruction slice spacing, convolution kernel, and acquisition slice thickness are relevant sources of radiomics variability with a percentage of robust features lower than 80%. Resampling to isometric voxels increased the number of robust features when images were acquired with different pixel sizes (p < 0.05). SVD-based for thickness correction and ComBat correction for thickness and combined thickness-kernel increased the number of reproducible features (p < 0.05). ComBat showed the highest improvement of radiomics-based classification in both the phantom and clinical applications (K-means purity 65.98 vs 73.20). Conclusion: CT-image post-acquisition processing and radiomics normalization by means of batch effect correction allow for standardization of large-scale data analysis and improve the classification accuracy
dc.format.extent11 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec710404
dc.identifier.issn0938-7994
dc.identifier.pmid32909055
dc.identifier.urihttps://hdl.handle.net/2445/176651
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1007/s00429-019-02009-1
dc.relation.ispartofEuropean Radiology, 2020, vol. 31, p. 1460-1470
dc.relation.urihttps://doi.org/10.1007/s00429-019-02009-1
dc.rightscc by (c) Ligero et al., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Biomedicina)
dc.subject.classificationCàncer
dc.subject.classificationMetàstasi
dc.subject.classificationMarcadors bioquímics
dc.subject.classificationTomografia
dc.subject.otherCancer
dc.subject.otherMetastasis
dc.subject.otherBiochemical markers
dc.subject.otherTomography
dc.titleMinimizing acquisition-related radiomics variability by image resampling and batch effect correction to allow for large-scale data analysis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
710404.pdf
Mida:
2.37 MB
Format:
Adobe Portable Document Format