Extubating of a patient undergoing mechanical ventilation: What is the right time? A retrospective study assisted by artificial intelligence techniques

dc.contributor.authorArismendi Pererira, Carlos Julio
dc.contributor.authorSandoval Rodríguez, Camilo Leonardo
dc.contributor.authorGiraldo Giraldo, Beatriz F. (Beatriz Fabiola)
dc.contributor.authorSolano, E. H.
dc.date.accessioned2025-07-30T09:37:31Z
dc.date.available2025-07-30T09:37:31Z
dc.date.issued2024-12-25
dc.date.updated2025-07-30T08:29:22Z
dc.description.abstractIn the presence of acute respiratory failure, mechanical ventilation emerges as a temporary alternative to maintain adequate gas exchange in the body such as that which occurs in natural respiration. This technique is widely used in intensive care units. Our objective was to carry out an analysis and interpretation of cardiorespiratory signals in patients assisted by mechanical ventilation, using non-linear analysis techniques of dynamic systems, data mining and machine learning techniques to establish indices that allow determining the appropriate moment of disconnection. in patients during the weaning process. We use three categories: Failure, success and reintubated. We introduced a new variant of Moving Window with Variance Analysis, with which good results are obtained. We have found that by using all the time series available in the database, we have obtained an accuracy of 96% when using simple symbolic dynamics to differentiate between successful weaning and reintubated cases. and 86% when comparing success and failure, which contrasts with the results observed in the state of the art.
dc.format.extent12 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idimarina6726280
dc.identifier.issn2303-4521
dc.identifier.urihttps://hdl.handle.net/2445/222693
dc.language.isoeng
dc.publisherInternational University of Sarajevo
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.21533/pen.v12.i3.60
dc.relation.ispartofPeriodicals of Engineering and Natural Sciences, 2024, vol. 12, num. 3, p. 604-615
dc.relation.urihttps://doi.org/10.21533/pen.v12.i3.60
dc.rightscc-by (c) Arismendi Pererira, Carlos Julio et al., 2024
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))
dc.subject.classificationRespiració artificial
dc.subject.classificationMedicina intensiva
dc.subject.otherArtificial respiration
dc.subject.otherCritical care medicine
dc.titleExtubating of a patient undergoing mechanical ventilation: What is the right time? A retrospective study assisted by artificial intelligence techniques
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
2024_PerEngNatSci_Extubating_GiraldoB.pdf
Mida:
482.05 KB
Format:
Adobe Portable Document Format