Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by-nc (c) Jorba-García, Adrià et al., 2024
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/217843

The influence of radiographic marker registration versus a markerless trace registration method on the implant placement accuracy achieved by dynamic computer-assisted implant surgery. An in-vitro study

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Objectives: This study aimed to compare the effect the radiographic marker registration (RMR) and markerless tracing registration (MTR) on implant placement accuracy using a dynamic computer-assisted implant surgery system (dCAIS). Additionally, this study aimed to assess the surgical time and whether the implant location influences the accuracy of the two registration methods. Methods: 136 dental implants were randomly allocated to the RMR or MTR group and were placed with a dCAIS in resin models. Preoperative and postoperative Cone Beam Computer Tomograms (CBCT) were overlaid and implant placement accuracy was assessed. Descriptive and multivariate analysis of the data was performed. Results: Significant differences (P < 0.001) were found for all accuracy variables except angular deviation (RMR:4.30° (SD:4.37°); MTR:3.89° (SD:3.32°)). The RMR had a mean 3D platform deviation of 1.53 mm (SD:0.98 mm) and mean apex 3D deviation of 1.63 mm (SD:1.05 mm) while the MTR had lower values (0.83 mm (SD:0.67 mm) and 1.07 mm (SD:0.86 mm), respectively). In the MTR group, implant placement in the anterior mandible was more accurate (p < 0.05). Additionally, MTR did not significantly increase the surgical time compared with RMR (P = 0.489). Conclusions: MTR seems to increase the accuracy of implant placement using dCAIS in comparison with the RMR method, without increasing the surgical time. The operated area seems to be relevant and might influence the implant deviations. Clinical significance: Considering the limitations of this in-vitro study, MTR seems to provide a higher accuracy in implant placement using dCAIS without increasing the surgical time. Furthermore, this method does not require radiographic markers and allows re-registration during surgery.

Citació

Citació

JORBA GARCÍA, Adrià, BARA CASAUS, Javier, CAMPS FONT, Octavi, BARBOSA DE FIGUEIREDO, Rui pedro, VALMASEDA CASTELLÓN, Eduardo. The influence of radiographic marker registration versus a markerless trace registration method on the implant placement accuracy achieved by dynamic computer-assisted implant surgery. An in-vitro study. _Journal of Dentistry_. 2024. Vol. 146. [consulta: 11 de abril de 2026]. ISSN: 0300-5712. [Disponible a: https://hdl.handle.net/2445/217843]

Exportar metadades

JSON - METS

Compartir registre