Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by-nc-nd (c) Casadei et al., 2020
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/173719

Peer inter-laboratory validation study of a harmonized SPME-GC-FID method for the analysis of selected volatile compounds in virgin olive oils

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

In the context of supporting the panel test in the classification of virgin olive oils, the qualitative and quantitative analysis of a number of volatile compounds responsible for their aroma is of great importance. Herein, the data obtained from three laboratories that analyzed the same samples are presented with the view to develop an inter-laboratory validation study of a harmonized solid-phase micro-extraction coupled with gas-chromatography with flame ionized detector (SPME-GC-FID) method for determination of selected volatile compounds. In particular, quantification of the minimum number of key markers responsible for positive attributes (e.g. fruity) and sensory defects was investigated. Three quantification strategies were considered since they can have a notable impact on the effectiveness of the use of markers as well as on the robustness and simplicity of the method that is designed for control laboratories. A peer-validation study indicated repeatability with a mean relative standard deviation (RSD%) lower than 14% except for ethyl propanoate, 3-methyl-1-butanol, 1-octen-3-ol, and (E)-2-decenal. Linearity was satisfactory (R2 > 0.90) for all compounds when the calibration curves were corrected by the internal standard. Several critical issues were identified, such as high RSD% (>50%) in terms of reproducibility for ethyl propanoate, (E)-2-decenal, and possible improvements of the limits of detection (LODs) and quantitation (LOQs) of (E)-2-heptenal, (E,E)-2,4-hexadienal, and (E)-2-decenal. In particular, some compounds (ethyl propanoate, (E)-2-heptenal, 1-octen-3-ol, (E,E)-2,4-hexadienal, (E)-2-decenal and pentanoic acid) showed LOQs that were higher than the concentrations found in some samples. The discussion permitted improvement of the protocol towards the final version for an upcoming full validation process.

Citació

Citació

CASADEI, Enrico, VALLI, Enrico, APARICIO RUIZ, Ramón, ORTIZ-ROMERO, Clemente, GARCÍA-GONZÁLEZ, Diego luis, VICHI, S. (stefania), QUINTANILLA-CASAS, Beatriz, TRES OLIVER, Alba, BENDINI, Alessandra, GALLINA TOSCHI, Tullia. Peer inter-laboratory validation study of a harmonized SPME-GC-FID method for the analysis of selected volatile compounds in virgin olive oils. _Food Control_. 2020. Vol. 123, núm. 107823. [consulta: 20 de gener de 2026]. ISSN: 0956-7135. [Disponible a: https://hdl.handle.net/2445/173719]

Exportar metadades

JSON - METS

Compartir registre