Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Published version

Publication date

Publication license

cc-by (c), Quinto, Levio et al., 2021
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/185184

Ventricular tachycardia burden reduction after substrate ablation: predictors of recurrence.

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

BACKGROUND Substrate-based ventricular tachycardia (VT) ablation is a first-line treatment in patients with structural cardiac disease and sustained VT refractory to medical therapy. Despite technological improvements and increased knowledge of VT substrate, recurrence still is frequent. Published data are lacking on the possible reduction in VT burden after ablation despite recurrence. OBJECTIVE The purpose of this study was to assess VT burden reduction during long-term follow-up after substrate ablation and identify predictors of VT recurrence. METHODS We analyzed 234 consecutive VT ablation procedures in 207 patients (age 63 6 14.9 years; 92% male; ischemic heart disease in 65%) who underwent substrate ablation in a single center from 2013 to 2018. RESULTS After follow-up of 3.14 6 1.8 years, the VT recurrence rate was 41.4%. Overall, a 99.6% reduction in VT burden (median VT episodes per year: preprocedural 3.546 [1.347-13.951] vs postprocedural 0.001 [0-0.689]; P 5 .001) and a 96.3% decrease in implantable cardioverter-defibrillator (ICD) shocks (preprocedural 1.145 [0.118-4.467] vs postprocedural 0.042 [0-0.111] per year; P 5 .017) were observed. In the subgroup of patients who experienced VT recurrences, VT burden decreased by 69.2% (median VT episodes per year: preprocedural 2.876 [1.105-8.801] vs postprocedural 0.882 [0.505-2.283]; P ,.001). Multivariable analysis showed persistence of late potentials (67% vs 19%; hazard ratio 3.18 [2.18- 6.65]; P ,.001) and lower left ventricular ejection fraction (EF) (30 [25-40] vs 39 [30-50]; P 5 .022) as predictors of VT recurrence. CONCLUSION Despite a high recurrence rate during long-term follow-up, substrate-based VT ablation is related to a large reduction in VT burden and a decrease in ICD therapies. Lower EF and persistence of late potentials are predictors of recurrence. KEYWORDS Arrhythmic burden reduction; Implantable cardioverter-defibrillator shock prevention; Ventricular tachycardia ablation; Ventricular tachycardia recurrence predictors; Ventricular tachycardia storm; Ventricular tachycardia substrate ablation

Citation

Citation

QUINTO, Levio, et al. Ventricular tachycardia burden reduction after substrate ablation: predictors of recurrence. Heart Rhythm. 2021. Vol. 18, num. 6, pags. 896-904. ISSN 1547-5271. [consulted: 11 of August of 2026]. Available at: https://hdl.handle.net/2445/185184

Export metadata

JSON - METS

Share record