Voltammetric determination of antihypertensive drug hydrochlorothiazide using screen-printed electrodes modified with L- glutamic acid
| dc.contributor.author | González-Vargas, Camilo | |
| dc.contributor.author | Serrano i Plana, Núria | |
| dc.contributor.author | Ariño Blasco, Cristina | |
| dc.contributor.author | Salazar, Ricardo | |
| dc.contributor.author | Esteban i Cortada, Miquel | |
| dc.contributor.author | Díaz Cruz, José Manuel | |
| dc.date.accessioned | 2017-10-02T07:24:34Z | |
| dc.date.available | 2017-10-02T07:24:34Z | |
| dc.date.issued | 2017-09-17 | |
| dc.date.updated | 2017-10-02T07:24:34Z | |
| dc.description.abstract | This work deals with the development of screen-printed carbon electrodes modified with L-glutamic acid via two different approaches: electropolymerization (SPCE/PGA) and aryl diazonium electrochemical grafting (SPCE/EGA). SPCE/PGA and SPCE/EGA were analytically compared in the determination of hydrochlorothiazide (HCTZ) by differential pulse voltammetry. Both electrochemical characterization and analytical performance indicate that SPCE/EGA is a much better sensor for HCTZ. The detection and quantification limits were at the level of micromol L-1 with a very good linearity in the studied concentration range. In addition, the proposed SPCE/EGA was successfully applied for the determination of HCTZ in an anti-hypertensive drug with high reproducibility and good trueness. | |
| dc.format.extent | 12 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 673372 | |
| dc.identifier.issn | 2227-9040 | |
| dc.identifier.uri | https://hdl.handle.net/2445/116084 | |
| dc.language.iso | eng | |
| dc.publisher | MDPI | |
| dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.3390/chemosensors5030025 | |
| dc.relation.ispartof | Chemosensors, 2017, vol. 5, num. 25, p. 1-12 | |
| dc.relation.uri | https://doi.org/10.3390/chemosensors5030025 | |
| dc.rights | cc-by (c) González-Vargas, Camilo et al., 2017 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es | |
| dc.source | Articles publicats en revistes (Enginyeria Química i Química Analítica) | |
| dc.subject.classification | Anàlisi electroquímica | |
| dc.subject.classification | Voltametria | |
| dc.subject.other | Electrochemical analysis | |
| dc.subject.other | Voltammetry | |
| dc.title | Voltammetric determination of antihypertensive drug hydrochlorothiazide using screen-printed electrodes modified with L- glutamic acid | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion |
Fitxers
Paquet original
1 - 1 de 1