Catheter tip distensibility substantially influences the aspiration force of thrombectomy devices

dc.contributor.authorLi, Jun
dc.contributor.authorCastaño Linares, Óscar
dc.contributor.authorTomasello, Alejandro
dc.contributor.authorDios Lascuevas, Marta de
dc.contributor.authorCanals, Pere
dc.contributor.authorEngel, Elisabeth
dc.contributor.authorRibó Jacobi, Marc
dc.date.accessioned2025-03-04T16:17:22Z
dc.date.available2025-03-04T16:17:22Z
dc.date.issued2021-12-01
dc.date.updated2025-03-04T16:17:22Z
dc.description.abstractBackground A direct aspiration first pass thrombectomy (ADAPT) is a fast-growing technique for which a broad catalog of catheters that provide a wide range of aspiration forces can be used. We aimed to characterize different catheters' aspiration performance on stiff clots in an in vitro vascular model. We hypothesized that labeled catheter inner diameter (labeled-ID) is not the only parameter that affects the aspiration force (asp-F) and that thrombus–catheter tip interaction and distensibility also play a major role. Methods We designed an experimental setup consisting of a 3D-printed carotid artery immersed in a water deposit. We measured asp-F and distensibility of catheter tips when performing ADAPT on a stiff clot analog larger than catheter labeled-ID. Correlations between asp-F, catheter ID, and tip distensibility were statistically assessed. Results Experimental asp-F and catheter labeled-ID were correlated (r=0.9601; P<0.01). The relative difference between experimental and theoretical asp-F (obtained by the product of the tip’s section area by the vacuum pressure) correlated with tip’s distensibility (r=0.9050; P<0.01), evidencing that ADAPT performance is highly influenced by catheter tip shape-adaptability to the clot and that the effective ID (eff-ID) may differ from the labeled-ID specified by manufacturers. Eff-ID showed the highest correlation with experimental asp-F (r=0.9944; P<0.01), confirming that eff-ID rather than labeled-ID should be considered to better estimate the device efficiency. Conclusions Catheter tip distensibility can induce a significant impact on ADAPT performance when retrieving a stiff clot larger than the device ID. Our findings might contribute to optimizing thrombectomy strategies and the design of novel aspiration catheters.
dc.format.extent5 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec714949
dc.identifier.issn1759-8478
dc.identifier.urihttps://hdl.handle.net/2445/219445
dc.language.isoeng
dc.publisherBMJ Publishing Group
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1136/neurintsurg-2021-017487
dc.relation.ispartofJournal of Neurointerventional Surgery, 2021, p. 1-5
dc.relation.urihttps://doi.org/10.1136/neurintsurg-2021-017487
dc.rightscc-by-nc (c) Li, J. et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationCatèters
dc.subject.classificationTrombosi
dc.subject.otherCatheters
dc.subject.otherThrombosis
dc.titleCatheter tip distensibility substantially influences the aspiration force of thrombectomy devices
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion