Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Document type

Article

Version

Accepted version

Publication date

All rights reserved

Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/121933

Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions

Journal Title

Director/Tutor

Journal ISSN

Volume Title

Abstract

PURPOSE: This study was conducted to test, in mountain running route conditions, the accuracy of the Polar V800 monitor as a suitable device for monitoring the heart rate variability (HRV) of runners. METHOD: Eighteen healthy subjects ran a route that included a range of running slopes such as those encountered in trail and ultra-trail races. The comparative study of a V800 and a Holter SEER 12 ECG Recorder included the analysis of RR time series and short-term HRV analysis. A correction algorithm was designed to obtain the corrected Polar RR intervals. Six 5-min segments related to different running slopes were considered for each subject. RESULTS: The correlation between corrected V800 RR intervals and Holter RR intervals was very high (r = 0.99, p < 0.001), and the bias was less than 1 ms. The limits of agreement (LoA) obtained for SDNN and RMSSD were (- 0.25 to 0.32 ms) and (- 0.90 to 1.08 ms), respectively. The effect size (ES) obtained in the time domain HRV parameters was considered small (ES < 0.2). Frequency domain HRV parameters did not differ (p > 0.05) and were well correlated (r ≥ 0.96, p < 0.001). CONCLUSION: Narrow limits of agreement, high correlations and small effect size suggest that the Polar V800 is a valid tool for the analysis of heart rate variability in athletes while running high endurance events such as marathon, trail, and ultra-trail races. KEYWORDS: HRV; Open field running conditions; Polar V800 heart rate monitor; Validation

Citation

Citation

CAMINAL MAGRANS, Pere, et al. Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions. European Journal of Applied Physiology. 2018. Vol. 118, num. 3, pags. 669-677. ISSN 1439-6319. [consulted: 12 of August of 2026]. Available at: https://hdl.handle.net/2445/121933

Export metadata

JSON - METS

Share record