Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by-nc-nd (c) Domínguez-Carretero, Diego et al., 2024
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/227495

Accurate electron probe microanalysis of key petrogenetic minor and trace elements in Cr-spinel

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

The trace element composition of Cr-spinel is paramount for interpreting the petrogenesis of a large group of mafic to ultramafic rocks. Although laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has proven to be very useful for the determination of trace element abundances of Cr-spinel, the characterization of Cr-spinel grains that are inhomogeneous over micrometer length scales requires the use of techniques that provide a better spatial resolution than LA-ICP-MS. In this work, we develop a protocol for the determination of trace and minor elements in Cr-spinel by electron probe microanalysis (EPMA) using the software provided by the manufacturer. The optimized analytical conditions (25 kV accelerating voltage, 900 nA beam current, 60–480 s peak counting times, aggregate spectrometer data) allowed us to achieve detection limits (3σ) in the range 4–26 ppm with relative analytical precisions (2σ) in the range 1–3 % for all analyzed elements (Ti, V, Mn, Co, Ni, and Zn), except for Sc and Ga, for which the precision was much lower (36–46 %). The developed methodology was applied to the analysis of Cr-spinel grains from the Mayarí-Baracoa Ophiolitic Belt (eastern Cuba), in correspondence with previous LA-ICP-MS analyses, which were used to assess the reliability of the EPMA results. The root mean square percentage deviation (RMS) between the EPMA and LA-ICP-MS data was in the range 4.7–22.5 % for Ti, V, Mn, Co, Ni, and Zn, while for Ga the RMS value was 32.5 %. For Sc, the RMS value was much higher (171 %), despite the low detection limit achieved (4 ppm) for this element. Our results indicate that the trace element composition of primary Cr-spinel obtained by EPMA can be readily used, except for Sc, to constrain petrogenetic information on chromitites in a reliable way.

Citació

Citació

DOMÍNGUEZ-CARRETERO, Diego, et al. Accurate electron probe microanalysis of key petrogenetic minor and trace elements in Cr-spinel. Chemical Geology. 2024. Vol. 674. ISSN 0009-2541. [consulted: 15 of August of 2026]. Available at: https://hdl.handle.net/2445/227495

Exportar metadades

JSON - METS

Compartir registre