Development and validation of a high performance liquid chromatography method to determine linezolid concentrations in pig pulmonary tissue

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

Background: linezolid is the first synthetic compound of a new group of antimicrobials, the oxazolidinones, which inhibit protein synthesis. It shows a broad spectrum of activity against Gram positive organisms. With respect to its pharmacokinetics, linezolid shows a relatively high volume of distribution and good penetration into inflammatory fluids, bone, fat and muscle. Methods: a reversed-phase isocratic high-performance liquid chromatographic method for linezolid analysis in piglet pulmonary tissue is described. Tissue samples and controls were prepared in 1 x TBE (1 M Tris, 0.9 M boric acid, 0.01 M EDTA). The mobile phase consisted of 20% ultrafiltered water and 80% of (A) 15 mM potassium monohydrogen phosphate buffer (pH = 5) with (B) acetonitrile (80%/20%; v/v). Samples were homogenized and precipitated with HClO(4) 3% (1/1, v/v). The injection volume was 100 microL. Ofloxacin was used as an internal standard. Results: the assay was linear over a linezolid concentration range: 1.6-100 microg/mL. The method provided good validation data (n = 15): inaccuracy (3.6%), intra and inter-day variability (4.2% and 5.2%, respectively), recovery (91.8%), limit of detection (0.8 microg/mL) and quantitation (1.6 microg/mL) and acceptable stability within 24 h in the auto-sampler. Conclusions: the method offers a fast and simple approach to determine linezolid in pulmonary tissue which could be of use in pharmacokinetic studies.

Citació

Citació

GUERRERO MOLINA, Laura, et al. Development and validation of a high performance liquid chromatography method to determine linezolid concentrations in pig pulmonary tissue. Clinical Chemistry and Laboratory Medicine. 2010. Vol. 3, num. 48, pags. 391-398. ISSN 1434-6621. [consulted: 12 of August of 2026]. Available at: https://hdl.handle.net/2445/134028

Exportar metadades

JSON - METS

Compartir registre