Probing single-tooth dental implants with and without prostheses: a cross-sectional study comparing healthy and peri-implant mucositis sites

dc.contributor.authorGarcía-García, Marta
dc.contributor.authorMir-Mari, Javier
dc.contributor.authorBarbosa de Figueiredo, Rui Pedro
dc.contributor.authorValmaseda Castellón, Eduardo
dc.date.accessioned2025-01-22T19:01:05Z
dc.date.available2025-01-22T19:01:05Z
dc.date.issued2021-02-02
dc.date.updated2025-01-22T19:01:05Z
dc.description.abstractAim: To evaluate differences in probing depth (PPD) with and without a prosthesis in implants without interproximal bone loss (IBL). Secondarily, to assess whether the difference in PPD measured with and without the crown was affected by diagnosis or implant location. Materials and methods: A cross-sectional study was conducted in patients with a single screw-retained implant-supported crown in the posterior area, without IBL. PPD and was assessed before and after crown removal. A subgroup analysis compared healthy vs. mucositis implants and premolar vs. molar locations. Results: In the 62 implants analysed (23 healthy and 39 with mucositis), the PPD was 1.15 mm (SD = 1.24 mm) deeper without the prosthesis than with it (p < .001). This difference was independent of the implant location (p > .05) except for buccal sites (p = .048). The mean PPD difference for implants with mucositis was 0.95 mm (SD = 1.19 mm; p < .001) while healthy implants had a mean PPD variation of 1.47 mm (SD = 1.29 mm; p < .001). Conclusion: The presence of prosthesis in single-tooth implants in the posterior area without IBL seems to lead to an underestimation of PPD that appears to be significant in implants diagnosed with mucositis, although the difference is even greater in healthy implants. Further studies are needed to confirm these findings. Keywords: diagnosis; implant-supported dental prosthesis; peri-implantitis; probing; single-tooth dental implant.
dc.format.extent33 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec708395
dc.identifier.issn0303-6979
dc.identifier.pmid33527458
dc.identifier.urihttps://hdl.handle.net/2445/217847
dc.language.isoeng
dc.publisherJohn Wiley & Sons
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1111/jcpe.13436
dc.relation.ispartofJournal of Clinical Periodontology, 2021, vol. 48, num.4, p. 581-589
dc.relation.urihttps://doi.org/10.1111/jcpe.13436
dc.rights(c) John Wiley & Sons, 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationImplants dentals
dc.subject.classificationPròtesis dentals
dc.subject.classificationInflamació
dc.subject.otherDental implants
dc.subject.otherDental prosthesis
dc.subject.otherInflammation
dc.titleProbing single-tooth dental implants with and without prostheses: a cross-sectional study comparing healthy and peri-implant mucositis sites
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
235912.pdf
Mida:
479.27 KB
Format:
Adobe Portable Document Format