Color stability of CAD/CAM interim material for long-term fixed dental prostheses vs. conventional materials after immersion in different staining solutions

dc.contributor.authorPeñate, Lissethe
dc.contributor.authorMercadé Bellido, Montserrat
dc.contributor.authorArregui, María
dc.contributor.authorRoig, Miguel
dc.contributor.authorBasilio Monné, Juan
dc.contributor.authorCedeño, Rosario
dc.date.accessioned2021-05-21T10:35:15Z
dc.date.available2021-05-21T10:35:15Z
dc.date.issued2021-04-13
dc.date.updated2021-05-21T10:35:16Z
dc.description.abstractThe color stability of interim computer-aided design and computer-assisted manufacturing (CAD/CAM) materials has not been exhaustively investigated. The aim of this study was to com- pare the translucency (TP) and contrast ratio (CR) of CAD/CAM blocks and conventional interim materials, as well as the effects of varnish application and tooth-brushing on color stability after immersion in different staining solutions. Four hundred and eighty specimens were fabricated with four different interim materials (n = 120) and were divided into three experimental, and one control group (n = 30). The color measurements were taken at the initial time (T0), 24 h (T1), 7 days (T2), and 30 days (T3) after immersion in different solutions. CIEDE2000 (∆E00) values were analyzed with ANOVA and Fischer's LSD test with a 95% confidence interval. The relationship between TP and CR was analyzed with a Pearson correlation. All interim materials showed a significant difference (p < 0.05) in color change after 30 days. Results showed that polyethyl methacrylate resins (PEMA) had the highest stability over time. The TP and CR were statistically significant (p < 0.05). It was observed that brushing improved the color stability but the ∆E00 were the highest when the varnish alone or varnish and brushing were used, except in the bis-acryl group, in which varnish and brushing decreased the color stainability.
dc.format.extent12 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec711705
dc.identifier.issn2504-477X
dc.identifier.urihttps://hdl.handle.net/2445/177442
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/jcs5040106
dc.relation.ispartofJournal of Composite Science, 2021, vol. 5, num. 106
dc.relation.urihttps://doi.org/10.3390/jcs5040106
dc.rightscc-by (c) Peñate, Lissethe et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationColor
dc.subject.classificationPròtesis dentals
dc.subject.classificationSistemes CAD-CAM
dc.subject.classificationMaterials dentals
dc.subject.otherColor
dc.subject.otherDental prosthesis
dc.subject.otherCAD/CAM systems
dc.subject.otherDental materials
dc.titleColor stability of CAD/CAM interim material for long-term fixed dental prostheses vs. conventional materials after immersion in different staining solutions
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
711705.pdf
Mida:
1.03 MB
Format:
Adobe Portable Document Format