Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study

dc.contributor.authorRuiz-Romero, Víctor
dc.contributor.authorJorba García, Adrià
dc.contributor.authorCamps Font, Octavi
dc.contributor.authorBarbosa de Figueiredo, Rui Pedro
dc.contributor.authorValmaseda Castellón, Eduardo
dc.date.accessioned2025-01-22T18:30:07Z
dc.date.available2025-01-22T18:30:07Z
dc.date.issued2024-10-01
dc.date.updated2025-01-22T18:30:07Z
dc.description.abstractObjectives: To compare miniscrew versus bone tracing registration methods on dental implant placement accuracy and time efficiency in edentulous jaws using a dynamic computer-assisted implant surgery (d-CAIS) system. Methods: Twelve fully edentulous maxillary models were allocated into two groups: miniscrew tracing (MST) group, where registration was performed by tracing four miniscrews; and bone tracing (BT) group, where registration was conducted by tracing maxillary bone fiducial landmarks. Six implants were placed on each model using the X-Guide® d-CAIS system. Pre- and postoperative cone-beam computed tomography (CBCT) scans were superimposed to evaluate implant placement accuracy. The time required for registration and the overall surgery time were also recorded. Results: Thirty-six implants were placed in each group. The MST group showed significantly lower mean angulation deviations (mean difference (MD): -3.33°; 95 % confidence interval (CI): -6.56 to -0.09); p = 0.044), 3D platform deviations (MD: -1.01 mm; 95 % CI: -1.74 to -0.29; p = 0.006), 2D platform deviations (MD: -0.97 mm; 95 % CI: -1.71 to -0.23; p = 0.010), and 3D apex deviations (MD: -1.18 mm; 95 % CI: -1.92 to -0.44; p = 0.002) versus the BT group. The overall surgery time was similar for both groups (MD: 6.10 min.; 95 % CI: -0.31 to 12.51; p = 0.06), though bone tracing required significantly more time compared with miniscrew registration (MD: 4.79 min.; 95 % CI: 2.96 to 6.62; p < 0.05). Conclusions: Registration with MST increases the accuracy of implant placement with a d-CAIS system in edentulous jaws compared with the BT method, and slightly reduces the overall surgery time.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec750710
dc.identifier.issn0300-5712
dc.identifier.pmid39106900
dc.identifier.urihttps://hdl.handle.net/2445/217844
dc.language.isoeng
dc.publisherElsevier
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.jdent.2024.105290
dc.relation.ispartofJournal of Dentistry, 2024, vol. 149
dc.relation.urihttps://doi.org/10.1016/j.jdent.2024.105290
dc.rightscc-by-nc-nd (c) Ruiz-Romero, Víctor et al., 2024
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationTomografia
dc.subject.classificationImplants dentals intraossis
dc.subject.classificationMaxil·lars
dc.subject.otherTomography
dc.subject.otherEndosseous dental implants
dc.subject.otherJaws
dc.titleAccuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
867668.pdf
Mida:
4.69 MB
Format:
Adobe Portable Document Format