Reproducibility of optical coherence tomography airway imaging

dc.contributor.authorKirby, Miranda
dc.contributor.authorOhtani, Keishi
dc.contributor.authorNickens, Taylor
dc.contributor.authorLopez Lisbona, Rosa Maria
dc.contributor.authorLee, Anthony M. D.
dc.contributor.authorShaipanich, Tawimas
dc.contributor.authorLane, Pierre
dc.contributor.authorMacaulay, Calum
dc.contributor.authorLam, Stephen
dc.contributor.authorCoxson, Harvey O.
dc.date.accessioned2018-09-03T11:34:18Z
dc.date.available2018-09-03T11:34:18Z
dc.date.issued2015-11-01
dc.date.updated2018-07-25T07:56:49Z
dc.description.abstractOptical coherence tomography (OCT) is a promising imaging technique to evaluate small airway remodeling. However, the short-term insertion-reinsertion reproducibility of OCT for evaluating the same bronchial pathway has yet to be established. We evaluated 74 OCT data sets from 38 current or former smokers twice within a single imaging session. Although the overall insertion-reinsertion airway wall thickness (WT) measurement coefficient of variation (CV) was moderate at 12%, much of the variability between repeat imaging was attributed to the observer; CV for repeated measurements of the same airway (intra-observer CV) was 9%. Therefore, reproducibility may be improved by introduction of automated analysis approaches suggesting that OCT has potential to be an in-vivo method for evaluating airway remodeling in future longitudinal and intervention studies. (C) 2015 Optical Society of America
dc.format.extent13 p.
dc.format.mimetypeapplication/pdf
dc.identifier.pmid26601002
dc.identifier.urihttps://hdl.handle.net/2445/124213
dc.language.isoeng
dc.publisherOSA Publishing
dc.relation.isformatofReproducció del document publicat a: http://dx.doi.org/10.1364/BOE.6.004365
dc.relation.ispartofBiomedical Optics Express, 2015, vol. 6, num. 11, p. 4365-4377
dc.relation.urihttp://dx.doi.org/10.1364/BOE.6.004365
dc.rights(c) Optical Society, 2015
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
dc.subject.classificationÒptica fisiològica
dc.subject.classificationBiotecnologia
dc.subject.otherPhysiological optics
dc.subject.otherBiotechnology
dc.titleReproducibility of optical coherence tomography airway imaging
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
KirbyM.pdf
Mida:
1.74 MB
Format:
Adobe Portable Document Format