Ion release and local effects of titanium metal particles from dental implants: an experimental study in rats

dc.contributor.authorToledano Serrabona, Jorge
dc.contributor.authorCamps Font, Octavi
dc.contributor.authorPompéu de Moraes, Diogo
dc.contributor.authorCorte-Rodríguez, Mario
dc.contributor.authorMontes-Bayón, Maria
dc.contributor.authorValmaseda Castellón, Eduardo
dc.contributor.authorGay Escoda, Cosme
dc.contributor.authorSánchez Garcés, Ma. Ángeles
dc.date.accessioned2022-11-11T18:29:45Z
dc.date.available2022-11-11T18:29:45Z
dc.date.issued2022-06-09
dc.date.updated2022-11-11T18:29:45Z
dc.description.abstractBackground: The objective of this study was to evaluate the accumulation of ions in blood and organs caused by Ti metal particles in a mandibular defect in rats, together with a description of the local reaction of oral tissues to these titanium alloy debris. Methods: Twenty Sprague-Dawley rats were randomly distributed into three groups: an experimental group with a mandibular bone defect filled with metallic debris obtained by implantoplasty; a positive control group; and a negative control group. Thirty days after surgery, the rats were euthanized and perilesional tissue surrounding the mandibular defect was removed, together with the lungs, spleen, liver and brain. Two blood samples were collected: immediately before surgery and before euthanasia. The perilesional tissue was histologically analyzed using hematoxylin-eosin staining, and titanium, aluminum and vanadium ion concentrations in blood and organs were measured by TQ-ICP-MS. Descriptive and bivariate analyses of the data were performed. Results: All rats with implanted metal debris showed metal particles and a bone fracture callus on the osseous defect. The metal particles were surrounded by a foreign body reaction characterized by the presence of histiocytes and multinucleated giant cells. The experimental group had a significant higher concentration of Ti ions in all studied organs except lung tissue (p < 0.05). In addition, there were more V ions in the brain in the experimental group (p = 0.008). Conclusions: Although further studies are required to confirm the clinical relevance of these results, Ti metal particles in the jaw might increase the concentration of metal ions in vital organs and induce a foreign body reaction. This article is protected by copyright. All rights reserved. Keywords: Ion release; Ti6Al4V; implantoplasty; metal particles; peri-implantitis; titanium.
dc.format.extent11 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec724265
dc.identifier.issn0022-3492
dc.identifier.pmid35678251
dc.identifier.urihttps://hdl.handle.net/2445/190722
dc.language.isoeng
dc.publisherAmerican Academy of Periodontology
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1002/JPER.22-0091
dc.relation.ispartofJournal of Periodontology, 2022
dc.relation.urihttps://doi.org/10.1002/JPER.22-0091
dc.rightscc by-nc-nd (c) Toledano-Serrabona, Jorge et al., 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationExperimentació animal
dc.subject.classificationImplants dentals
dc.subject.classificationTitani
dc.subject.classificationMaxil·lars
dc.subject.otherAnimal experimentation
dc.subject.otherDental implants
dc.subject.otherTitanium
dc.subject.otherJaws
dc.titleIon release and local effects of titanium metal particles from dental implants: an experimental study in rats
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion