Kappa free light chains is a valid tool in the diagnostics of MS: A large multicenter study

dc.contributor.authorLeurs, C. E.
dc.contributor.authorTwaalfhoven, H.
dc.contributor.authorLissenberg-Witte, B. I.
dc.contributor.authorvan Pesch, V.
dc.contributor.authorDujmovic, Irena
dc.contributor.authorDrulovic, J.
dc.contributor.authorCastellazzi, M.
dc.contributor.authorBellini, T.
dc.contributor.authorPugliatti, M.
dc.contributor.authorKuhle, J.
dc.contributor.authorVillar, Luisa M.
dc.contributor.authorÁlvarez Cermeño, José C.
dc.contributor.authorAlvarez Lafuente, R.
dc.contributor.authorHegen, H.
dc.contributor.authorDeisenhammer, F.
dc.contributor.authorWalchhofer, L. M.
dc.contributor.authorThouvenot, E.
dc.contributor.authorComabella, Manuel
dc.contributor.authorMontalbán Gairín, Xavier
dc.contributor.authorSaiz Hinarejos, Albert
dc.contributor.authorPuma, D. La
dc.contributor.authorVercammen, M.
dc.contributor.authorVanopdenbosch, L.
dc.contributor.authorUitdehaag, B. M. J.
dc.contributor.authorKillestein, J.
dc.contributor.authorBridel, C.
dc.contributor.authorTeunissen, C.
dc.date.accessioned2021-01-11T14:15:43Z
dc.date.available2021-01-11T14:15:43Z
dc.date.issued2020
dc.date.updated2021-01-11T14:15:43Z
dc.description.abstractObjective: To validate kappa free light chain (KFLC) and lambda free light chain (LFLC) indices as a diagnostic biomarker in multiple sclerosis (MS). Methods: We performed a multicenter study including 745 patients from 18 centers (219 controls and 526 clinically isolated syndrome (CIS)/MS patients) with a known oligoclonal IgG band (OCB) status. KFLC and LFLC were measured in paired cerebrospinal fluid (CSF) and serum samples. Gaussian mix- ture modeling was used to define a cut-off for KFLC and LFLC indexes. Results: The cut-off for the KFLC index was 6.6 (95% confidence interval (CI) = 5.2-138.1). The cut-off for the LFLC index was 6.9 (95% CI=4.5-22.2). For CIS/MS patients, sensitivity of the KFLC index (0.88; 95% CI = 0.85-0.90) was higher than OCB (0.82; 95%CI = 0.79-0.85; p < 0.001), but specificity (0.83; 95% CI = 0.78-0.88) was lower (OCB = 0.92; 95% CI = 0.89-0.96; p < 0.001). Both sensitivity and specificity for the LFLC index were lower than OCB. Conclusion: Compared with OCB, the KFLC index is more sensitive but less specific for diagnosing CIS/MS. Lacking an elevated KFLC index is more powerful for excluding MS compared with OCB but the latter is more important for ruling in a diagnosis of CIS/MS.
dc.format.extent12 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec690300
dc.identifier.issn1352-4585
dc.identifier.pmid31066634
dc.identifier.urihttps://hdl.handle.net/2445/173069
dc.language.isoeng
dc.publisherSAGE Publications
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1177/1352458519845844
dc.relation.ispartofMultiple Sclerosis Journal, 2020, vol. 26, num. 8, p. 912-923
dc.relation.urihttps://doi.org/10.1177/1352458519845844
dc.rightscc by-nc (c) Leurs et al., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/es/
dc.sourceArticles publicats en revistes (Medicina)
dc.subject.classificationEsclerosi múltiple
dc.subject.classificationMarcadors bioquímics
dc.subject.otherMultiple sclerosis
dc.subject.otherBiochemical markers
dc.titleKappa free light chains is a valid tool in the diagnostics of MS: A large multicenter study
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
690300.pdf
Mida:
399.88 KB
Format:
Adobe Portable Document Format