Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis

dc.contributor.authorJorba García, Adrià
dc.contributor.authorGonzález-Barnadas, Albert
dc.contributor.authorCamps Font, Octavi
dc.contributor.authorBarbosa de Figueiredo, Rui Pedro
dc.contributor.authorValmaseda Castellón, Eduardo
dc.date.accessioned2025-01-22T19:14:55Z
dc.date.available2025-01-22T19:14:55Z
dc.date.issued2021-02-26
dc.date.updated2025-01-22T19:14:55Z
dc.description.abstractObjectives: To assess the accuracy of dynamic computer-aided implant surgery (dCAIS) systems when used to place dental implants and to compare its accuracy with static computer-aided implant surgery (sCAIS) systems and freehand implant placement. Materials and methods: An electronic search was made to identify all relevant studies reporting on the accuracy of dCAIS systems for dental implant placement. The following PICO question was developed: 'In patients or artificial models, is dental implant placement accuracy higher when dCAIS systems are used in comparison with sCAIS systems or with freehand placement? The main outcome variable was angular deviation between the central axes of the planned and final position of the implant. The data were extracted in descriptive tables, and a meta-analysis of single means was performed in order to estimate the deviations for each variable using a random-effects model. Results: Out of 904 potential articles, the 24 selected assessed 9 different dynamic navigation systems. The mean angular and entry 3D global deviations for clinical studies were 3.68° (95% CI: 3.61 to 3.74; I2 = 99.4%) and 1.03 mm (95% CI: 1.01 to 1.04; I2 = 82.4%), respectively. Lower deviation values were reported in in vitro studies (mean angular deviation of 2.01° (95% CI: 1.95 to 2.07; I2 = 99.1%) and mean entry 3D global deviation of 0.46 mm (95% CI: 0.44 to 0.48 ; I2 = 98.5%). No significant differences were found between the different dCAIS systems. These systems were significantly more accurate than sCAIS systems (mean difference (MD): -0.86°; 95% CI: -1.35 to -0.36) and freehand implant placement (MD: -4.33°; 95% CI: -5.40 to -3.25). Conclusion: dCAIS systems allow highly accurate implant placement with a mean angular of less than 4°. However, a 2-mm safety margin should be applied, since deviations of more than 1 mm were observed. dCAIS systems increase the implant placement accuracy when compared with freehand implant placement and also seem to slightly decrease the angular deviation in comparison with sCAIS systems. Clinical relevance: The use of dCAIS could reduce the rate of complications since it allows a highly accurate implant placement.
dc.format.extent37 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec708393
dc.identifier.issn1432-6981
dc.identifier.pmid33635397
dc.identifier.urihttps://hdl.handle.net/2445/217849
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1007/s00784-021-03833-8
dc.relation.ispartofClinical Oral Investigations, 2021, vol. 25, num.5, p. 2479-2494
dc.relation.urihttps://doi.org/10.1007/s00784-021-03833-8
dc.rights(c) German Society of Oral and Maxillofacial Surgery, 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationDisseny assistit per ordinador
dc.subject.classificationOrdinadors
dc.subject.classificationTomografia
dc.subject.classificationImplants dentals
dc.subject.otherComputer-aided design
dc.subject.otherComputers
dc.subject.otherTomography
dc.subject.otherDental implants
dc.titleAccuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
235910.pdf
Mida:
1.06 MB
Format:
Adobe Portable Document Format