Interrater reliability and agreement of the NEUMOBACT checklist about infection prevention performance of intensive care nurses in simulation-based scenarios

dc.contributor.authorRaurell Torredà, Marta
dc.contributor.authorZaragoza-García, Ignacio
dc.contributor.authorArrogante, Oscar
dc.contributor.authorAliberch Raurell, Anna
dc.contributor.authorSánchez-Chillón, Francisco Javier
dc.contributor.authorTorralba-Melero, Martín
dc.contributor.authorRojo-Rojo, Andrés
dc.contributor.authorMuriel-García, Alfonso
dc.contributor.authorAmaya-Arias, Ana Carolina
dc.contributor.authorRoldán Merino, Juan Francisco
dc.contributor.authorFarrés-Tarafa, Mariona
dc.date.accessioned2025-01-08T19:10:20Z
dc.date.available2025-01-08T19:10:20Z
dc.date.issued2024-12-31
dc.date.updated2025-01-08T19:10:20Z
dc.description.abstractObjective: To analyse the interrater reliability of the NEUMOBACT checklist and verify whether consistent results are reproducible. Methods: A validation study with a cross-sectional design, compliant with the GRRAS checklist,among ICU nurses attending a SIMULAZERO course with an Objective Structured Clinical Evaluation simulation format, to verify transfer from theory to clinical practice of knowledge and skills in ventilator-associated pneumonia (VAP) and catheter-related bacteraemia (CRB) prevention. A minimum sample size of 111 pairs of nurse raters was calculated. Interrater agreement was analysed using Gwet’s AC1 for each item and as a total for each of thethree checklists in the NEUMOBACT instrument. Results: A total of 95 pairs of valid NEUMOBACT checklists were completed by 190 raters with amedian age of 29 [25–35] years, 93.7% were female. At the Central Venous Catheter insertion station, Gwet’s AC1 was 0.934 (95% CI [0.919–0.949]). Only 2 of the 17 items scored below 0.9. At the Endotracheal Suctioning station, Gwet’s AC1 was 0.869 (95% CI [0.851–0.886]). Of the 26 items that made up this station, 16 had an agreement percentage above0.9, a further 9 were between 0.821 and 0.884, and item 13 had a value of 0.789. At the Patient Care station, Gwet’s AC1 was 0.911 (95% CI [0.896–0.927]). Of the 21 items, 17 showed an agreement percentage above 0.9 and 4 were between 0.810 and 0.894. Conclusions: The interrater reliability of the NEUMOBACT checklist shows substantial agreement between pairs of raters and is therefore validated in this large sample of ICU nurses.
dc.format.extent12 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec752906
dc.identifier.issn1932-6203
dc.identifier.pmid39739706
dc.identifier.urihttps://hdl.handle.net/2445/217334
dc.language.isoeng
dc.publisherPublic Library of Science (PLoS)
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1371/journal.pone.0313175
dc.relation.ispartofPLoS One, 2024, vol. 19, num.12
dc.relation.urihttps://doi.org/10.1371/journal.pone.0313175
dc.rightscc-by (c) Raurell-Torredà, M. et al., 2024
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Infermeria Fonamental i Clínica)
dc.subject.classificationCatèters
dc.subject.classificationUnitats de cures intensives
dc.subject.classificationSang
dc.subject.classificationInfeccions
dc.subject.otherCatheters
dc.subject.otherIntensive care units
dc.subject.otherBlood
dc.subject.otherInfections
dc.titleInterrater reliability and agreement of the NEUMOBACT checklist about infection prevention performance of intensive care nurses in simulation-based scenarios
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
874236.pdf
Mida:
522.78 KB
Format: