Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants

dc.contributor.authorCosta-Berenguer, Xavier
dc.contributor.authorSánchez Torres, Alba
dc.contributor.authorSanz Alonso, Mariano
dc.contributor.authorBarbosa de Figueiredo, Rui Pedro
dc.contributor.authorValmaseda Castellón, Eduardo
dc.contributor.authorGarcía-García, Marta
dc.date.accessioned2025-01-30T19:02:51Z
dc.date.available2025-01-30T19:02:51Z
dc.date.issued2017-07-23
dc.date.updated2025-01-30T19:02:52Z
dc.description.abstractObjective: To assess the effect of implantoplasty on the fracture resistance, surface roughness, and macroscopic morphology of standard diameter (4.1 mm) external connection dental implants.Materials and methods: An in vitro study was conducted in 20 screw-shaped titanium dental implants with an external connection. In 10 implants, the threads and surface were removed and polished with high-speed burs (implantoplasty), while the remaining 10 implants were used as controls. The final implant dimensions were recorded. The newly polished surface quality was assessed by scanning electron microscopy (SEM) and by 3D surface roughness analysis using a confocal laser microscope. Finally, all the implants were subjected to a mechanical pressure resistance test. A descriptive analysis of the data was made. Also, Student's t tests were employed to detect differences regarding the compression tests.Results: Implantoplasty was carried out for a mean time of 10 min and 48 s (standard deviation (SD) of 1 min 22 s). Macroscopically, the resulting surface had a smooth appearance, although small titanium shavings and silicon debris were present. The final surface roughness (Sa values 0.1 +/- 0.02 mu m) was significantly lower than that of the original (0.75 +/- 0.08 mu m Sa) (p = .005). There was minimal reduction in the implant's inner body diameter (0.19 +/- 0.03 mm), and no statistically significant differences were found between the test and control implants regarding the maximum resistance force (896 vs 880 N, respectively).Conclusions: Implantoplasty, although technically demanding and time-consuming, does not seem to significantly alter fracture resistance of standard diameter external connection implants. A smooth surface with Sa values below 0.1 mu m can be obtained through the use of silicon polishers. A larger sample is required to confirm that implantoplasty does not significantly affect the maximum resistance force of standard diameter external -connection implants.
dc.format.extent28 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec686032
dc.identifier.issn0905-7161
dc.identifier.pmid28736922
dc.identifier.urihttps://hdl.handle.net/2445/218292
dc.language.isoeng
dc.publisherJohn Wiley & Sons
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1111/clr.13037
dc.relation.ispartofClinical Oral Implants Research, 2017, vol. 29, num.1, p. 46-54
dc.relation.urihttps://doi.org/10.1111/clr.13037
dc.rights(c) John Wiley & Sons Ltd, 2017
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationInflamació
dc.subject.classificationImplants dentals
dc.subject.classificationHigiene dental
dc.subject.otherInflammation
dc.subject.otherDental implants
dc.subject.otherDental hygiene
dc.titleEffect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
214808.pdf
Mida:
892.39 KB
Format:
Adobe Portable Document Format