Vertical and Horizontal Ridge Augmentation with Titanium-Reinforced Dense PTFE and Reinforced PTFE Mesh: A Prospective Comparative Case Series
Títol de la revista
Director/Tutor
Contribució addicional
ISSN de la revista
Títol del volum
Resum
Objectives: This study aimed to compare vertical bone gain (VBG) and horizontal bone gain (HBG) after guided bone regeneration using titanium-reinforced dense PTFE (TiR-dPTFE) versus reinforced PTFE mesh (RPM) at 9 and 12 months on three-dimensional tomographic imaging, and to perform histological assessment in selected cases. Materials and Methods: This prospective comparative case series included 14 patients (46 vertical ridge defect sites) treated with guided bone regeneration using either Ti-reinforced dPTFE membranes (TiR-dPTFE; n = 23) or resorbable porcine collagen membranes (RPM; n = 23). All sites received a 60:40 mixture of autogenous bone chips and anorganic bovine bone mineral (ABBM). After 9 months, during implant placement, a protective secondary augmentation using a 70:30 ABBM/autogenous mixture was performed and covered with a collagen membrane. Vertical and horizontal bone gain (VBG, HBG) were assessed on standardized matched CBCT cross-sections obtained at 9 and 12 months. Core biopsies were harvested at implant placement (9 months) for histological evaluation. Surgical and healing complications were recorded. Results: Both membranes produced significant VBG. TiR-dPTFE achieved greater VBG than RPM at 9 months (p = 0.045) and 12 months (p = 0.012) and remained stable from 9 to 12 months, whereas RPM showed a significant decline over time (MDa −0.48 mm; 95% CI −0.64 to −0.31; p < 0.001). HBG was similar between groups at both time points (p = 0.918 and p = 0.922). No major clinical complications occurred. Histology at 9 months confirmed vital bone formation and graft integration in both groups. Conclusions: Both TiR-dPTFE and RPM are reliable options for vertical ridge augmentation; TiR-dPTFE yielded superior and more stable vertical gains over 12 months, with comparable horizontal outcomes. Clinical Relevance: TiR-dPTFE may offer enhanced vertical augmentation, while both membranes remain suitable for implant site development.
Recurs relacionat
Matèries
Matèries (anglès)
Citació
Citació
SILVA, Liliana Andrea, et al. Vertical and Horizontal Ridge Augmentation with Titanium-Reinforced Dense PTFE and Reinforced PTFE Mesh: A Prospective Comparative Case Series. Journal of Functional Biomaterials. 2026. Vol. 17, num. 5. ISSN 2079-4983. [consulted: 2 of October of 2026]. Available at: https://hdl.handle.net/2445/231708