Vertical and Horizontal Ridge Augmentation with Titanium-Reinforced Dense PTFE and Reinforced PTFE Mesh: A Prospective Comparative Case Series

dc.contributor.authorSilva, Liliana Andrea
dc.contributor.authorGomes, Pedro Sousa
dc.contributor.authorFernandes, Maria Helena
dc.contributor.authorGarcía García, Marta
dc.contributor.authorCamps Font, Octavi
dc.date.accessioned2026-09-25T13:52:56Z
dc.date.available2026-09-25T13:52:56Z
dc.date.issued2026-05-07
dc.date.updated2026-09-25T13:52:57Z
dc.description.abstractObjectives: This study aimed to compare vertical bone gain (VBG) and horizontal bone gain (HBG) after guided bone regeneration using titanium-reinforced dense PTFE (TiR-dPTFE) versus reinforced PTFE mesh (RPM) at 9 and 12 months on three-dimensional tomographic imaging, and to perform histological assessment in selected cases. Materials and Methods: This prospective comparative case series included 14 patients (46 vertical ridge defect sites) treated with guided bone regeneration using either Ti-reinforced dPTFE membranes (TiR-dPTFE; n = 23) or resorbable porcine collagen membranes (RPM; n = 23). All sites received a 60:40 mixture of autogenous bone chips and anorganic bovine bone mineral (ABBM). After 9 months, during implant placement, a protective secondary augmentation using a 70:30 ABBM/autogenous mixture was performed and covered with a collagen membrane. Vertical and horizontal bone gain (VBG, HBG) were assessed on standardized matched CBCT cross-sections obtained at 9 and 12 months. Core biopsies were harvested at implant placement (9 months) for histological evaluation. Surgical and healing complications were recorded. Results: Both membranes produced significant VBG. TiR-dPTFE achieved greater VBG than RPM at 9 months (p = 0.045) and 12 months (p = 0.012) and remained stable from 9 to 12 months, whereas RPM showed a significant decline over time (MDa −0.48 mm; 95% CI −0.64 to −0.31; p < 0.001). HBG was similar between groups at both time points (p = 0.918 and p = 0.922). No major clinical complications occurred. Histology at 9 months confirmed vital bone formation and graft integration in both groups. Conclusions: Both TiR-dPTFE and RPM are reliable options for vertical ridge augmentation; TiR-dPTFE yielded superior and more stable vertical gains over 12 months, with comparable horizontal outcomes. Clinical Relevance: TiR-dPTFE may offer enhanced vertical augmentation, while both membranes remain suitable for implant site development.
dc.format.extent18 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec772303
dc.identifier.issn2079-4983
dc.identifier.pmid42188401
dc.identifier.urihttps://hdl.handle.net/2445/231708
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/jfb17050234
dc.relation.ispartofJournal of Functional Biomaterials, 2026, vol. 17, num.5
dc.relation.urihttps://doi.org/10.3390/jfb17050234
dc.rightscc-by (c) Silva, L.A. et al., 2026
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.classificationOssos de la cara
dc.subject.classificationImplants dentals
dc.subject.otherFacial bones
dc.subject.otherDental implants
dc.titleVertical and Horizontal Ridge Augmentation with Titanium-Reinforced Dense PTFE and Reinforced PTFE Mesh: A Prospective Comparative Case Series
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
944153.pdf
Mida:
1.7 MB
Format:
Adobe Portable Document Format