Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Physicochemical properties and interfacial adaptation of root canal sealers.

dc.contributor.authorCañadas, Piedad S.
dc.contributor.authorBerástegui, Esther
dc.contributor.authorGatón Hernández, Patrícia
dc.contributor.authorSilva, Léa Assed Bezerra da
dc.contributor.authorLeite, Giselle A.
dc.contributor.authorSilva, Roberto S.
dc.date.accessioned2015-11-23T09:36:12Z
dc.date.available2015-11-23T09:36:12Z
dc.date.issued2014-09
dc.date.updated2015-11-23T09:36:12Z
dc.description.abstractThis study compared the physicochemical properties and interfacial adaptation to canal walls of Endo-CPM-Sealer, Sealapex and Activ GP with the well-established AH Plus sealer. The following analyses were performed: radiopacity, pH variation and solubility using samples of each material and scanning electron microscopy of root-filled bovine incisors to evaluate the interfacial adaptation. Data were analyzed by the parametric and no-parametric tests (α=0.05). All materials were in accordance with the ANSI/ADA requirements for radiopacity. Endo-CPM-Sealer presented the lowest radiopacity values and AH Plus was the most radiopaque sealer (p=0.0001). Except for ActiV GP, which was acidic, all other sealers had basic chemical nature and released hydroxyl ions. Regarding solubility, all materials met the ANSI/ADA recommendations, with no statistically significant difference between the sealers (p=0.0834). AH Plus presented the best adaptation to canal walls in the middle (p=0.0023) and apical (p=0.0012) thirds, while the sealers Activ GP and Endo-CPM-Sealer had poor adaptation to the canal walls. All sealers, except for ActiV GP, were alkaline and all of them fulfilled the ANSI/ADA requirements for radiopacity and solubility. Regarding the interfacial adaptation, AH Plus was superior to the others considering the adaptation to the bovine root canal walls.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec646222
dc.identifier.issn0103-6440
dc.identifier.urihttps://hdl.handle.net/2445/67891
dc.language.isoeng
dc.publisherDental Foundation of Ribeirão Preto
dc.relation.isformatofReproducció del document publicat a: http://dx.doi.org/10.1590/0103-6440201300037
dc.relation.ispartofBrazilian Dental Journal , 2014, vol. 25, num. 5, p. 435-441
dc.relation.urihttp://dx.doi.org/10.1590/0103-6440201300037
dc.rightscc-by-nc (c) Cañadas, Piedad S. et al., 2014
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/es
dc.sourceArticles publicats en revistes (Odontoestomatologia)
dc.subject.classificationMaterials dentals
dc.subject.classificationEndodòncia
dc.subject.classificationDentina
dc.subject.otherDental materials
dc.subject.otherEndodontics
dc.subject.otherDentin
dc.titlePhysicochemical properties and interfacial adaptation of root canal sealers.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
646222.pdf
Mida:
475 KB
Format:
Adobe Portable Document Format