Integrated seismic ambient noise, magnetotellurics and gravity data for the 2D interpretation of the Vallès basin structure in the geothermal system of La Garriga-Samalús (NE Spain)

dc.contributor.authorMitjanas Colls, Gemma
dc.contributor.authorLedo Fernández, Juanjo
dc.contributor.authorMacau, A.
dc.contributor.authorAlías López, Gemma
dc.contributor.authorQueralt i Capdevila, Pilar
dc.contributor.authorBellmunt Traver, Fabián
dc.contributor.authorRivero Marginedas, Lluís
dc.contributor.authorGabàs, A.
dc.contributor.authorMarcuello Pascual, Alejandro
dc.contributor.authorBenjumea Moreno, Beatriz
dc.contributor.authorMartí, A.
dc.contributor.authorFigueras, S.
dc.date.accessioned2021-12-21T15:34:25Z
dc.date.available2021-12-21T15:34:25Z
dc.date.issued2021-06-01
dc.date.updated2021-12-21T15:34:25Z
dc.description.abstractThe integration of geophysical methods, together with the previous information of the Vallès basin area, has resulted in the creation of a new conceptual model that explains La Garriga-Samalús geothermal system. The integration of complementary geophysical methods seems to be a good option for the preliminary stages of a geothermal system exploration, especially in urban areas. An integrated seismic ambient noise, magnetotellurics, and gravity methods were used to determine the geological units and structures which control the La Garriga-Samalús geothermal system. The 2D resistivity and density models have allowed the identification of the four main units which regulate the geothermal system: the Miocene basin, the Prelitoral Range unit, the Vallès Faut Zone, and the Paleozoic basement. The interpretation of our models set the Vallès Fault Zone, which is characterized by an anomalous low resistivity and low density, as the main path for the hot fluids. Moreover, the geophysical characterization established a new geometry for the Miocene basin. The Miocene basin presents a stepwise morphology, with the minor thickness towards the fault and an increasing thickness towards the center of the basin. This geometry seems to be related to synthetic normal faults. These results have evidenced that, although, in some geothermal systems, the warm water may create an insufficient physical contrast; the appropriate use of some techniques can still be useful for the exploration of medium and low-temperature geothermal systems.
dc.format.extent14 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec710724
dc.identifier.issn0375-6505
dc.identifier.urihttps://hdl.handle.net/2445/181936
dc.language.isoeng
dc.publisherElsevier
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.geothermics.2021.102067
dc.relation.ispartofGeothermics, 2021, vol. 93, p. 102067
dc.relation.urihttps://doi.org/10.1016/j.geothermics.2021.102067
dc.rightscc-by-nc-nd (c) Elsevier, 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Mineralogia, Petrologia i Geologia Aplicada)
dc.subject.classificationProspecció geofísica
dc.subject.classificationEscorça terrestre
dc.subject.classificationGeomagnetisme
dc.subject.otherGeophysical exploration
dc.subject.otherEarth's crust
dc.subject.otherGeomagnetism
dc.titleIntegrated seismic ambient noise, magnetotellurics and gravity data for the 2D interpretation of the Vallès basin structure in the geothermal system of La Garriga-Samalús (NE Spain)
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
710724.pdf
Mida:
7.86 MB
Format:
Adobe Portable Document Format